Skip to content
TapBuff

Town of Lovell

EPA’s and Wyoming’s records have results for 33 contaminants in its water; 2 were found.

Serves 2,250 people · Surface water bought from another system · Lovell, WY

Serves
2,250 people
Connections
1,104
Water source
Surface water bought from another system
Based in
Lovell, WY
County
Big Horn
Owner
Local government
The ZIP code it serves

82431

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Jan. 21 to Oct. 22, 2025.

Haloacetic acids (HAA5) and total trihalomethanes (TTHM): Wyoming’s own results, samples taken from Sept. 8, 2020 to Sept. 8, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 27 ppb

Highest yearly average, 2020 to 2026 · 2026, one sample: 13 ppb · Forms or is added in treatment

Averaged by year, the highest was 27 ppb, in 2020, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 25 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 27 ppb

Highest yearly average, 2020 to 2026 · 2026, one sample: 14 ppb · Forms or is added in treatment

Averaged by year, the highest was 27 ppb, in 2020, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 28 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Utilities above EPA’s PFAS limits, state by state⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Disinfectant

Town of Lovell reported adding chloramine before water enters its pipes, at its one sampling point, in its 2025 sampling for EPA. It also reported permanganate.

What that means

Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are Wyoming’s own from 2020 on, with EPA’s national file for 2012 to 2019. Town of Lovell’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 21 to Oct. 22, 2025; Wyoming’s results run from Sept. 8, 2020 to Sept. 8, 2026.

Testing your own tap

Town of Lovell’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Wyoming certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Town of Lovell’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The lab Wyoming certifies closest to the area Town of Lovell serves, or a kit by mail

The lab Wyoming certifies closest to the area Town of Lovell serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pace Analytical Services LLC WY

    Sheridan, WY · about 65 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, radioactivity

    (307) 461-4938

All 12 certified labs for Wyoming⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Wyoming certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Wyoming’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID WY5600031. Rebuilt from EPA data on Oct. 25, 2026.