TapBuff

Wheeling water quality report, rewritten

Serves
29,899
Connections
13,185
Water source
Surface water
Based in
Wheeling, WV
County
Ohio
Owner
Local government
The 6 ZIP codes it serves

15376, 26003, 26032, 26059, 26060, 26074

PWSID WV33035162026 edition · EPA data

Read this first

Nothing in the federal data for this utility is above a health goal. That covers PFAS, lithium, lead and copper; it does not cover everything, so read what this report cannot tell you below.

4 health-based violations since 2016. Details are below.

What was found

Highlighted: above the health goal, or EPA’s health benchmark where there is no goal. Circled: above the legal limit in at least one sample, or the action level. Every scale puts that line at its middle.

PFHxS

Comes from the source

3.3ppt

Highest of 4 samples; found in one

Detected, below the legal limit and the health goal.

What handles it

  • NSF/ANSI 53Look for: Total PFAS ReductionSame claim, other certifiers’ wording: Perfluorohexane Sulfonic Acid (PFHxS)

NSF’s PFAS claims are tested to below 20 ppt. EPA’s limit is 10 ppt, and EPA says no certification yet shows a filter reaching its levels.

EPA UCMR 5, samples taken on May 8, 2024. Each blue tick is one sample where it was found.

PFBS

Comes from the source

3.7ppt

Highest of 4 samples; found in three

Below EPA’s hazard index benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own.

What handles it

EPA UCMR 5, samples taken from Feb. 15, 2024 to Nov. 13, 2024. Each blue tick is one sample where it was found.

Tested and not found

Below EPA’s minimum reporting level in every sample taken from Feb. 15, 2024 to Nov. 13, 2024. Not found means not measured above that level, which is not the same as zero.

All 29 compounds tested and not found
  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lead
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Long Term 2 Enhanced Surface Water Treatment RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyAug. 1, 2025—Unaddressed
Long Term 2 Enhanced Surface Water Treatment RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyAug. 1, 2025—Unaddressed
Long Term 2 Enhanced Surface Water Treatment RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyFeb. 10, 2021—Resolved
Long Term 2 Enhanced Surface Water Treatment RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyFeb. 13, 2018—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown.

What this report cannot tell you

  • Levels of everything else. Federal bulk data carries results for PFAS, lithium, lead and copper, and violations for the rest. Nitrate, arsenic, disinfection byproducts and other levels are in Wheeling’s own annual report, which it must send you every year.
  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
  • Anything after the latest data. SDWIS data is from 2026 Q2; UCMR 5 samples are from Feb. 15, 2024 to Nov. 13, 2024.

What to do next

  1. Nothing here is above a health goal

    In the federal data for this utility. That data does not cover everything, which is why the next step matters.

    Every contaminant TapBuff tracks
  2. Get the utility’s own report

    Wheeling must send you a water quality report every year. It lists nitrate, arsenic and byproduct levels this page cannot.

    How to read it
  3. Test your own tap for lead

    Your service line, solder and fixtures decide the lead at your faucet, not the utility’s average.

    Lead in your water: what to do
  4. Decide if you want a filter at all

    A filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.

    NSF/ANSI standards, decoded