The short answer
None of the results here is above a limit in force today. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
Haloacetic acids (HAA5), fluoride, total trihalomethanes (TTHM), nitrate, chromium (total) and arsenic: West Virginia’s own results, samples taken from Feb. 20, 2020 to Aug. 6, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
Below EPA’s limits, 5 results
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 29.4 ppb
Highest yearly average, 2020 to 2026 · 2026, one sample: 2.0 ppb · Forms or is added in treatment
Averaged by year, the highest was 29.4 ppb, in 2024, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 3.0 ppb, in 2014.
What handles it
No certification claim covers this compound yet.
Fluoride, Legal limit 4.0 ppm; highest yearly average 1.1 ppm
Highest yearly average, 2020 to 2026 · 2026, one sample: 0.72 ppm · Forms or is added in treatment
Averaged by year, the highest was 1.1 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 1.6 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.49 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 11.6 ppb
Highest yearly average, 2020 to 2026 · 2026, one sample: 3.0 ppb · Forms or is added in treatment
Averaged by year, the highest was 11.6 ppb, in 2023, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 9.3 ppb, in 2014.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Nitrate, Legal limit 10 ppm; highest 0.13 ppm
Highest sample; found in 4 of 7 · 2026, one sample: 0.13 ppm · Comes from the source
The highest sample, in 2020, was 0.13 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.19 ppm, in 2013.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Chromium (total), Legal limit 100 ppb; highest yearly average 0.57 ppb
Highest yearly average, 2022 to 2026 · 2026: not found · Comes from the source
Averaged by year, the highest was 0.57 ppb, in 2023, below EPA’s legal limit of 100 ppb. In 2026, the latest year on file, it wasn’t found in its one sample.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 26 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
What this report can’t tell you
Everything else. Haloacetic acids (HAA5), fluoride, total trihalomethanes (TTHM), nitrate, chromium (total) and arsenic results here are West Virginia’s own from 2020 on, with EPA’s national file for 2012 to 2019. Raleigh County PSD Coal City’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; West Virginia’s results run from Feb. 20, 2020 to Aug. 6, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Raleigh County PSD Coal City’s latest lead sampling in EPA’s records, 2024 to 2026, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs West Virginia certifies closest to the area Raleigh County PSD Coal City serves, or a kit by mail
The 3 labs West Virginia certifies closest to the area Raleigh County PSD Coal City serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Analabs, Inc.
Crab Orchard, WV · about 4 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, disinfection byproducts
Pace Analytical Services, LLC - Beaver
Beaver, WV · about 7 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, radioactivity
West Virginia Dept. of Health - Office of Lab Services, Chemistry
Charleston, WV · about 52 miles
Certified for nitrate, lead and copper, metals, minerals and other inorganics, disinfection byproducts
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that West Virginia certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against West Virginia’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded
- Get the utility’s own reportRaleigh County PSD Coal City must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- West Virginia Department of Health, Drinking Water Viewer, results from Jan. 3, 2020 to Oct. 15, 2026, read Oct. 25, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: West Virginia Office of Laboratory Services, laboratory certified parameter list, read Oct. 11, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID WV3304123. Rebuilt from EPA data on Oct. 25, 2026.