Skip to content
TapBuff

Pocahontas Co PSD - Cheat Mountain Water

EPA’s and West Virginia’s records have results for 8 contaminants in its water; 4 were found.

Serves 1,867 people · Surface water · Snowshoe Resort, WV

Serves
1,867 people
Connections
210
Water source
Surface water
Based in
Snowshoe Resort, WV
County
Pocahontas
Owner
Private
The ZIP code it serves

26209

The short answer

EPA recorded violations of the legal limit for total trihalomethanes (TTHM) here in 2024 and 2025. In 2026, the latest year on file, it averaged 49.3 ppb, below the limit. EPA recorded a violation of the legal limit for haloacetic acids (HAA5) here in 2022. In 2026, the latest year on file, it averaged 28.3 ppb, below the limit. 13 health-based violations since 2016, 3 with no fix on record in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠The 13 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

Lead and copper: EPA SDWIS monitoring periods ending 2018 to 2023.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic, chromium (total), fluoride and uranium: West Virginia’s own results, samples taken from Jan. 14, 2020 to Aug. 11, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

A legal-limit violation on record, below the limit in the latest year, 2 results

Total trihalomethanes (TTHM)

Forms or is added in treatment

Violation on record (2025)

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days. A filter certified for it, at the tap you drink from, reduces it.

87.5 ppb

Highest yearly average, 2020 to 2026

2026 average: 49.3 ppb

Averaged by year, the highest was 87.5 ppb, in 2024, above EPA’s legal limit of 80 ppb. Its highest single sample was 151 ppb. In 2026, the latest year on file, its three samples averaged below the limit. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2024 and 2025.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 86.5 ppb, in 2016, and EPA recorded violations in 2016, 2017 and 2019.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Violation on record (2022)

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days.

51.3 ppb

Highest yearly average, 2020 to 2026

2026 average: 28.3 ppb

Averaged by year, the highest was 51.3 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 82 ppb. In 2026, the latest year on file, its three samples averaged below the limit. EPA recorded a violation for haloacetic acids (HAA5) at this utility in 2022.

How it’s judged

EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 67.6 ppb, in 2016, and EPA recorded violations in 2016, 2017 and 2018.

What handles it

No certification claim covers this compound yet.

Below EPA’s limits, 2 results

Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Nitrate, Legal limit 10 ppm; highest 0.66 ppm

Highest sample; found in 6 of 7 · 2026: not found · Comes from the source

The highest sample, in 2020, was 0.66 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, it wasn’t found in its one sample.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.66 ppm, in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Lead, Action level 15 ppb · health goal zero; 90th percentile 0.24 ppb

90th percentile, 2023 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 0.24 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Fluoride
  • Uranium

Violations since 2016

13 health-based violations since 2016, 8 for TTHM and 5 for total Haloacetic Acids (HAA5). The latest began April 1, 2025, and 3 have no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2025 to June 30, 2025, 89 ppbResolved
Jan. 1, 2025 to March 31, 2025, 87 ppbResolved
Oct. 1, 2024 to Dec. 31, 2024, 88 ppbResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2022 to Sept. 30, 2022, 62 ppbResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2019 to Dec. 31, 2019, 84 ppbResolved
The other 8, back to 2016
Earlier health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2018 to Sept. 30, 2018, 63 ppbResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 2017, 84 ppbResolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 2017, 61 ppbResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 2017, 88 ppbNo fix on recordEPA: archived
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 2017, 62 ppbResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 2017, 88 ppbNo fix on recordEPA: archived
Oct. 1, 2016 to Dec. 31, 2016, 87 ppbNo fix on recordEPA: archived
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2016 to Dec. 31, 2016, 68 ppbResolved

Health-based violations only. 27 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

    Other claims that cover it: VOC Reduction

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for TTHM, ranked⁠

The best water filters for lead, ranked⁠

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic, chromium (total), fluoride and uranium results here are West Virginia’s own from 2020 on, with EPA’s national file for 2012 to 2019. Pocahontas Co PSD - Cheat Mountain Water’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; West Virginia’s results run from Jan. 14, 2020 to Aug. 11, 2026.

Testing your own tap

Pocahontas Co PSD - Cheat Mountain Water’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab West Virginia certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Pocahontas Co PSD - Cheat Mountain Water’s latest lead sampling in EPA’s records, 2023, had a 90th percentile of 0.24 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Pocahontas Co PSD - Cheat Mountain Water’s results flag: total trihalomethanes (TTHM) and haloacetic acids (HAA5). These are in the water the utility sends out, so a test of your tap mostly confirms them. Include them if you want a number for your own home.
The 2 labs West Virginia certifies closest to the area Pocahontas Co PSD - Cheat Mountain Water serves, or a kit by mail

The 2 labs West Virginia certifies closest to the area Pocahontas Co PSD - Cheat Mountain Water serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Sturm Environmental Services

    Bridgeport, WV · about 60 miles

    Certified for bacteria

  • West Virginia Department of Agriculture / Moorefield Field Office

    Moorefield, WV · about 67 miles

    Certified for bacteria

All 50 certified labs for West Virginia⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that West Virginia certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against West Virginia’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID WV3303808. Rebuilt from EPA data on Oct. 25, 2026.