Skip to content
TapBuff

Brenton PSD

EPA’s and West Virginia’s records have results for 7 contaminants in its water; 4 were found.

Serves 241 people · Groundwater · Brenton, WV

Serves
241 people
Connections
100
Water source
Groundwater
Based in
Brenton, WV
County
Wyoming
Owner
Private
The 3 ZIP codes it serves

24716, 24726, 24847

The short answer

EPA recorded violations of the legal limit for haloacetic acids (HAA5) here in 2022, 2023 and 2024. In 2025, the latest year on file, its one sample was 0 ppb, below the limit. Total trihalomethanes (TTHM) averaged above its legal limit’s level in 2020, with no violation recorded. 8 health-based violations since 2016, 2 with no fix on record in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠The 8 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 1.5 ppm, for the period ending June 30, 1994. None since is on file, so it is not counted as a current finding.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), chromium (total), nitrate, arsenic and fluoride: West Virginia’s own results, samples taken from Aug. 26, 2020 to Sept. 4, 2025, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

A legal-limit violation on record, below the limit in the latest year, 1 result

Haloacetic acids (HAA5)

Forms or is added in treatment

Violation on record (2024)

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days.

211 ppb

Highest yearly average, 2020 to 2025

2025: not found

Averaged by year, the highest was 211 ppb, in 2020, about 3.5 times EPA’s legal limit of 60 ppb. Its highest single sample was 296 ppb. In 2025, the latest year on file, it wasn’t found in its one sample. EPA recorded violations for haloacetic acids (HAA5) at this utility in 2022, 2023 and 2024.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 12.1 ppb, in 2017.

What handles it

No certification claim covers this compound yet.

Above the limit’s level, no violation recorded, 1 result

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the limit’s level, no violation

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A filter certified for it, at the tap you drink from, reduces it.

185 ppb

Highest yearly average, 2020 to 2025

2025, one sample: 2.0 ppb

Averaged by year, the highest was 185 ppb, in 2020, about 2.3 times EPA’s legal limit of 80 ppb. In 2025, the latest year on file, its one sample was below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

How it’s judged

EPA judges this limit on running averages at each sampling point. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 63 ppb, in 2012.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Chromium (total), Legal limit 100 ppb; highest yearly average 0.62 ppb

Highest yearly average, 2022 · Comes from the source

Averaged by year, the highest was 0.62 ppb, in 2022, below EPA’s legal limit of 100 ppb. That is the only year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 13.9 ppb, in 2013.

What handles it

About chromium (total)
Nitrate, Legal limit 10 ppm; highest 0.045 ppm

Highest sample; found in 1 of 6 · 2025: not found · Comes from the source

The highest sample, in 2020, was 0.045 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in its one sample.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.38 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Fluoride
  • Lead

Violations since 2016

8 health-based violations since 2016, 4 for the Groundwater Rule, 3 for total Haloacetic Acids (HAA5) and 1 for the Revised Total Coliform Rule. The latest began July 1, 2024, and 2 have no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2024 to Sept. 30, 2024, 94 ppbResolved
Revised Total Coliform RuleColiform results required a check of the system, and the check or its fixes were not done on time.EPA: Treatment Technique, Level 1 Assessment (RTCR)Nov. 22, 2023Resolved
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencySept. 1, 2023No fix on recordEPA: unaddressed
May 1, 2023No fix on recordEPA: unaddressed
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2023 to June 30, 2023, 159 ppbResolved
The other 3, back to 2018
Earlier health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Groundwater RuleRequired treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR)Oct. 1, 2022 to Oct. 31, 2022Resolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2022 to June 30, 2022, 126 ppbResolved
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyJan. 20, 2018Resolved

Health-based violations only. 166 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

    Other claims that cover it: VOC Reduction

  • NSF/ANSI 58

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for TTHM, ranked⁠

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), chromium (total), nitrate, arsenic and fluoride results here are West Virginia’s own from 2020 on, with EPA’s national file for 2012 to 2019. Brenton PSD’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; West Virginia’s results run from Aug. 26, 2020 to Sept. 4, 2025.

Testing your own tap

Brenton PSD’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab West Virginia certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Brenton PSD’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Brenton PSD’s results flag: haloacetic acids (HAA5) and total trihalomethanes (TTHM). These are in the water the utility sends out, so a test of your tap mostly confirms them. Include them if you want a number for your own home.
The 3 labs West Virginia certifies closest to the area Brenton PSD serves, or a kit by mail

The 3 labs West Virginia certifies closest to the area Brenton PSD serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Analabs, Inc.

    Crab Orchard, WV · about 16 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, disinfection byproducts

  • Pace Analytical Services, LLC - Beaver

    Beaver, WV · about 23 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, radioactivity

  • West Virginia Dept. of Health - Office of Lab Services, Chemistry

    Charleston, WV · about 61 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, disinfection byproducts

All 50 certified labs for West Virginia⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that West Virginia certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against West Virginia’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID WV3305504. Rebuilt from EPA data on Oct. 25, 2026.