Skip to content
TapBuff

Westbourne Acres

What EPA’s and Washington’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
94 people
Connections
35
Water source
Groundwater
Based in
College Place, WA
County
Walla Walla
Owner
Private
The ZIP code it serves

99323

The short answer

1 result is above EPA’s legal limit, and 2 more are above the health goal. The worst: Nitrate, above the legal limit. 5 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2001 to 2025.

Nitrate, arsenic, fluoride, total trihalomethanes (TTHM) and haloacetic acids (HAA5): Washington’s own results, samples taken from May 1, 2020 to Sept. 29, 2026, with EPA’s 2012 to 2019 file for earlier years.

Chromium (total): EPA’s compliance monitoring file, samples taken from Aug. 6, 2018 to Sept. 9, 2019. Newer results are in the utility’s annual water quality report.

Above the legal limit1

Nitrate

Comes from the source

Above the legal limit

14.2ppm

Highest sample; found in 133 of 150

2026 average: 7.4 ppm

From 2025 to 2026, eight samples were above EPA’s legal limit of 10 ppm, the highest 14.2 ppm in 2026. The next sample at the same point, within 30 days, kept the average above the limit for two; six came back under. That was also the latest year on file, and its 19 samples averaged 7.4 ppm. EPA recorded violations for nitrate at this utility in 2025 and 2026. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 13.4 ppm, in 2013, and EPA recorded a violation in 2012.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Above the health goal2

Lead

Comes from pipes, often your own

Above the health goal

6.7ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 6.7 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the health goal

3.6ppb

Highest yearly average, 2025

Averaged by year, the highest was 3.6 ppb, in 2025: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 7.3 ppb. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.0 ppb, in 2019.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits4

Fluoride

Forms or is added in treatment

Below EPA’s limits

3.5ppm

Highest yearly average, 2021 to 2026

2026 average: 3.1 ppm

Averaged by year, the highest was 3.5 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, its two samples averaged 3.1 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 3.3 ppm, in 2018.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

5.7ppb

Highest yearly average, 2024

Averaged by year, the highest was 5.7 ppb, in 2024, below EPA’s legal limit of 80 ppb. That is the only year on file.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

2.3ppb

Highest yearly average, 2024

Averaged by year, the highest was 2.3 ppb, in 2024, below EPA’s legal limit of 60 ppb. That is the only year on file.

What handles it

No certification claim covers this compound yet.

Chromium (total)

Comes from the source

Below EPA’s limits

2.0ppb

Highest yearly average, 2018 to 2019

Averaged by year, the highest was 2.0 ppb, in 2019, below EPA’s legal limit of 100 ppb. That was also the latest year on file.

What handles it

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Nitrate/Nitrite (30 ppm challenge), Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Nitrate, Lead, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Nitrate/Nitrite Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Nitrate, Lead, Arsenic

    Other certifiers’ wording: Nitrate; Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2026 to June 30, 202610.9 MG/LArchived
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleApril 1, 2026 to June 30, 202610.9 MG/LArchived
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2026 to March 31, 202614.2 MG/LArchived
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2026 to March 31, 202614.2 MG/LArchived
NitrateA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2025 to Dec. 31, 202514 MG/LArchived
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 35 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Nitrate, arsenic, fluoride, total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Washington’s own from 2020 on, with EPA’s national file for 2012 to 2019. Chromium (total) comes from EPA’s file alone, which ends in 2019. Westbourne Acres’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Washington’s results run from May 1, 2020 to Sept. 29, 2026; EPA’s compliance samples are from Aug. 6, 2018 to Sept. 9, 2019.

Testing your own tap

Westbourne Acres’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Washington certifies.

The 3 labs Washington certifies closest to the area Westbourne Acres serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Matrix Sciences International Inc. dba KTL

    Pasco, WA · about 14 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics

    (509) 547-3838

  • RJ Lee Group, Inc. Columbia Basin Analytical Laboratories

    Pasco, WA · about 14 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics

    (509) 792-1951

  • Benton-Franklin Health District Lab

    Kennewick, WA · about 15 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (509) 460-4206

All 84 certified labs for Washington

Sources

PWSID WA5395047. Rebuilt from EPA data on Oct. 18, 2026.