Skip to content
TapBuff

Wanapum Village

What EPA’s and Washington’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
305 people
Connections
36
Water source
Groundwater
Based in
Selah, WA
County
Grant
Owner
Local government

The short answer

2 results are above the health goal. The worst: Lead, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2003 to 2025.

Total trihalomethanes (TTHM), nitrate and haloacetic acids (HAA5): Washington’s own results, samples taken from Sept. 30, 2020 to Oct. 6, 2025, with EPA’s 2012 to 2019 file for earlier years.

Arsenic, fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from April 23, 2018 to April 9, 2019. Newer results are in the utility’s annual water quality report.

Above the health goal2

Lead

Comes from pipes, often your own

Above the health goal

5.2ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 5.2 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the health goal

0.13ppb

Highest yearly average, 2018 to 2019

2019, one sample: 0.1 ppb

Averaged by year, the highest was 0.13 ppb, in 2018: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2019, the latest year on file, its one sample was 0.1 ppb.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits4

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.62ppm

Highest yearly average, 2018 to 2019

2019, one sample: 0.57 ppm

Averaged by year, the highest was 0.62 ppm, in 2018, below EPA’s legal limit of 4.0 ppm. In 2019, the latest year on file, its one sample was 0.57 ppm.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

3.3ppb

Highest yearly average, 2022 to 2025

2025, one sample: 0.21 ppb

Averaged by year, the highest was 3.3 ppb, in 2022, below EPA’s legal limit of 80 ppb. Its highest single sample was 3.6 ppb. In 2025, the latest year on file, its one sample was 0.21 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 4.8 ppb, in 2019.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

0.1ppm

Highest sample; found in 1 of 11

2025: not found

The highest sample, in 2020, was 0.1 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in any of its two samples. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.46 ppm, in 2015.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Chromium (total)

Comes from the source

Below EPA’s limits

0.76ppb

Highest yearly average, 2018 to 2019

Averaged by year, the highest was 0.76 ppb, in 2019, below EPA’s legal limit of 100 ppb. That was also the latest year on file.

What handles it

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Haloacetic acids (HAA5)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

The best reverse osmosis systems, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), nitrate and haloacetic acids (HAA5) results here are Washington’s own from 2020 on, with EPA’s national file for 2012 to 2019. Arsenic, fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Wanapum Village’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Washington’s results run from Sept. 30, 2020 to Oct. 6, 2025; EPA’s compliance samples are from April 23, 2018 to April 9, 2019.

Testing your own tap

Wanapum Village’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Washington certifies.

No lab Washington certifies is within 75 miles of the area Wanapum Village serves on the state’s list. Some take samples by mail; the state’s page lists them all.

All 84 certified labs for Washington

Sources

PWSID WA5329082. Rebuilt from EPA data on Oct. 18, 2026.