Winhall Stratton F D 1
EPA’s and Vermont’s records have results for 37 contaminants in its water; 4 were found.
Serves 6,200 people · Groundwater · Stratton, VT
- Serves
- 6,200 people
- Connections
- 2,267
- Water source
- Groundwater
- Based in
- Stratton, VT
- County
- Windham
- Owner
- Local government
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 1 health-based violation since 2016, resolved in EPA’s file.
Filters for lead, if you want it lowerThe violationGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Feb. 18 to Aug. 20, 2025.
Lead and copper: EPA SDWIS monitoring periods ending 2022 to 2026.
Total trihalomethanes (TTHM), nitrate, fluoride, arsenic, chromium (total) and haloacetic acids (HAA5): Vermont’s own results, samples taken from Jan. 14, 2020 to Aug. 11, 2026, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Below EPA’s limits, 4 results
Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 51.4 ppb
Highest yearly average, 2020 to 2026 · 2026, one sample: 28.8 ppb · Forms or is added in treatment
Averaged by year, the highest was 51.4 ppb, in 2024, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 26.4 ppb, in 2016.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.9 ppb
90th percentile, 2026 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 1.9 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Nitrate, Legal limit 10 ppm; highest 0.32 ppm
Highest sample; found in 18 of 21 · 2026 average: 0.13 ppm · Comes from the source
The highest sample, in 2022, was 0.32 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its three samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.5 ppm, in 2014.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.12 ppm
Highest yearly average, 2026 · Forms or is added in treatment
Averaged by year, the highest was 0.12 ppm, in 2026, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.2 ppm. That is the only year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 0.1 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
33 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Arsenic
- Chromium (total)
- Haloacetic acids (HAA5)
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
1 health-based violation since 2016 for the Lead and Copper Rule. It began Jan. 1, 2025.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Lead and Copper Rule | OCCT/SOWT Treatment Installation/Demonstration | Jan. 1, 2025 | Resolved |
Health-based violations only. 28 monitoring or reporting violations not shown.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claim: Lead Reduction
For: Lead
- NSF/ANSI 58
Claim: Lead Reduction
For: Lead
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead
Frizzlife SK99 Under Sink Water Filter
Under-sink carbon
Five years: $590, household of 3, cartridges included
Certified for: Lead
2 more filters
Bluevua RO100ROPOT-Lite Countertop Reverse Osmosis System
Countertop reverse osmosis
Five years: $805, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead
Brondell Coral UC300 Under Sink Water Filtration System
Under-sink carbon
Five years: $900, household of 3, cartridges included
Certified for: Lead
Disinfectant
Winhall Stratton F D 1 reported disinfecting with chlorine, not chloramine, at all 3 of its sampling points, in its 2025 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), nitrate, fluoride, arsenic, chromium (total) and haloacetic acids (HAA5) results here are Vermont’s own from 2020 on, with EPA’s national file for 2012 to 2019. Winhall Stratton F D 1’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 18 to Aug. 20, 2025; Vermont’s results run from Jan. 14, 2020 to Aug. 11, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Winhall Stratton F D 1’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 1.9 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Vermont certifies closest to the area Winhall Stratton F D 1 serves, or a kit by mail
The 3 labs Vermont certifies closest to the area Winhall Stratton F D 1 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Nelson Analytical Lab, Keene Division
N. Swanzey, NH · about 32 miles
Certified for bacteria
(603) 357-2577Website: Nelson Analytical Lab, Keene Division
City of Rutland Water Laboratory
Rutland, VT · about 37 miles
Certified for bacteria
Endyne, Inc
Lake George, NY · about 46 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Vermont certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Vermont’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and Vermont’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportWinhall Stratton F D 1 must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Vermont Department of Environmental Conservation, Drinking Water and Groundwater Protection Division, results from Jan. 2, 2020 to Oct. 7, 2026, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Vermont Department of Health, laboratories certified for drinking water analysis, read Oct. 16, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID VT0005305. Rebuilt from EPA data on Oct. 25, 2026.