Skip to content
TapBuff

Spring Glen Water Company

What EPA’s and Utah’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
50 people
Connections
13
Water source
Groundwater
Based in
Stansbury Park, UT
County
Salt Lake
Owner
Private
The ZIP code it serves

84108

The short answer

2 results are above the health goal. The worst: Lead, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2001 to 2025.

Arsenic, nitrate, fluoride and chromium (total): Utah’s own results, samples taken from Dec. 17, 2020 to Dec. 10, 2025, with EPA’s 2012 to 2019 file for earlier years.

Haloacetic acids (HAA5) and total trihalomethanes (TTHM): EPA’s compliance monitoring file, samples taken from July 31, 2013 to Aug. 29, 2017. Newer results are in the utility’s annual water quality report.

Above the health goal2

Lead

Comes from pipes, often your own

Above the health goal

3.4ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 3.4 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the health goal

0.5ppb

Highest yearly average, 2022 to 2025

2025: not found

Averaged by year, the highest was 0.5 ppb, in 2022: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.8 ppb, in 2013.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits4

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

57.2ppb

Highest yearly average, 2013 to 2017

2017: not found

Averaged by year, the highest was 57.2 ppb, in 2013, below EPA’s legal limit of 60 ppb. In 2017, the latest year on file, it wasn’t found in its one sample.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

60.3ppb

Highest yearly average, 2013 to 2017

2017, one sample: 8.4 ppb

Averaged by year, the highest was 60.3 ppb, in 2013, below EPA’s legal limit of 80 ppb. In 2017, the latest year on file, its one sample was 8.4 ppb.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

1.8ppm

Highest sample; found in 6 of 6

2025, one sample: 0.63 ppm

The highest sample, in 2021, was 1.8 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its one sample was 0.63 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 3.6 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.14ppm

Highest yearly average, 2022 to 2025

2025, one sample: 0.11 ppm

Averaged by year, the highest was 0.14 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, its one sample was 0.11 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.2 ppm, in 2013.

What handles it

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

The best reverse osmosis systems, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Arsenic, nitrate, fluoride and chromium (total) results here are Utah’s own from 2020 on, with EPA’s national file for 2012 to 2019. Haloacetic acids (HAA5) and total trihalomethanes (TTHM) come from EPA’s file alone, which ends in 2019. Spring Glen Water Company’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Utah’s results run from Dec. 17, 2020 to Dec. 10, 2025; EPA’s compliance samples are from July 31, 2013 to Aug. 29, 2017.

Testing your own tap

Spring Glen Water Company’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Utah certifies.

The 3 labs Utah certifies closest to the area Spring Glen Water Company serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Central Valley Water Relamation Facility

    South Salt Lake, UT · about 12 miles

    Certified for bacteria, lead and copper, metals, minerals and other inorganics

    (801) 973-9100

  • Utah Department of Health Division of Lab Services (EPA cert.)

    Taylorsville, UT · about 15 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, disinfection byproducts, PFAS

    (801) 965-2400

  • Chemtech-Ford, Inc.

    Sandy, UT · about 19 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity

    (801) 262-7299

All 60 certified labs for Utah

Sources

PWSID UTAH18043. Rebuilt from EPA data on Oct. 18, 2026.