Interlaken Town
What EPA’s and Utah’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 350 people
- Connections
- 148
- Water source
- Groundwater
- Based in
- Heber City, UT
- County
- Wasatch
- Owner
- Private
The ZIP code it serves
The short answer
2 results are above the health goal. The worst: Arsenic, above the health goal. 4 health-based violations since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2004 to 2024.
Arsenic, fluoride, chromium (total) and nitrate: Utah’s own results, samples taken from Oct. 1, 2020 to Sept. 22, 2025, with EPA’s 2012 to 2019 file for earlier years.
Above the health goal2
Arsenic
Comes from the source
1.7ppb
Highest yearly average, 2022 to 2025
Averaged by year, the highest was 1.7 ppb, in 2025: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.3 ppb, in 2013.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Lead
Comes from pipes, often your own
1.0ppb
90th percentile, 2022 to 2024
In the latest period, 9 in 10 homes sampled were at or below 1.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Below EPA’s limits1
Fluoride
Forms or is added in treatment
0.41ppm
Highest yearly average, 2022 to 2025
2025, one sample: 0.3 ppm
Averaged by year, the highest was 0.41 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, its one sample was 0.3 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.49 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Chromium (total)
- Nitrate
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Arsenic, Lead
Other certifiers’ wording: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Arsenic, Lead
Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Arsenic, Lead
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic, Lead
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Arsenic, Lead
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Groundwater Rule | A significant problem found in a state inspection was not fixed on time.EPA: Failure To Address Deficiency | March 3, 2019 | — | Resolved |
| Revised Total Coliform Rule | E. coli was confirmed in the water system.EPA: Maximum Contaminant Level Violation, E. coli (RTCR) | Sept. 1, 2017 to Sept. 30, 2017 | — | Resolved |
| Coliform (TCR) | Too many samples in a month tested positive for coliform bacteria.EPA: Maximum Contaminant Level Violation, Monthly (TCR) | Feb. 1, 2016 to Feb. 29, 2016 | — | Resolved |
| Coliform (TCR) | Too many samples in a month tested positive for coliform bacteria.EPA: Maximum Contaminant Level Violation, Monthly (TCR) | Jan. 1, 2016 to Jan. 31, 2016 | — | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown. | ||||
What this report can’t tell you
Everything else. Arsenic, fluoride, chromium (total) and nitrate results here are Utah’s own from 2020 on, with EPA’s national file for 2012 to 2019. Interlaken Town’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Utah’s results run from Oct. 1, 2020 to Sept. 22, 2025.
Testing your own tap
The 3 labs Utah certifies closest to the area Interlaken Town serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Wasatch County Health Department
Heber City, UT · about 6 miles
Certified for bacteria
Jordanelle Laboratory
Heber City, UT · about 8 miles
Certified for bacteria
Chemtech-Ford, Inc.
Sandy, UT · about 20 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Utah Department of Environmental Quality, Division of Drinking Water, results from Jan. 3, 2020 to Oct. 1, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Utah Department of Environmental Quality, Division of Drinking Water, certified laboratories, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID UTAH26055. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Arsenic
- Get the utility’s own reportInterlaken Town must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs