Maynardville Water Dept
EPA’s and CDC’s records have results for 35 contaminants in its water; 8 were found.
Serves 7,940 people · Surface water bought from another system · Maynardville, TN
- Serves
- 7,940 people
- Connections
- 3,042
- Water source
- Surface water bought from another system
- Based in
- Maynardville, TN
- County
- Union
- Owner
- Local government
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 1 health-based violation since 2016, resolved in EPA’s file.
Filters for lead and arsenic, if you want them lowerThe violationGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from March 12 to Dec. 9, 2025.
Lead and copper: EPA SDWIS monitoring periods ending 2004 to 2025.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate and arsenic: Tennessee’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2022, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
PFAS: PFBS was found, of the six PFAS in EPA’s 2024 drinking water rule; its result is below. Two other PFAS with no federal limit were found, the highest PFBA at 6.2 ppt: see them below.
Below EPA’s limits, 6 results
Lead and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health benchmark:
- A screening level EPA uses where there is no legal limit or health goal, not an enforceable limit.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 21.2 ppb
Highest yearly average, 2020 to 2022 · 2022 average: 13.3 ppb · Forms or is added in treatment
Averaged by year, the highest was 21.2 ppb, in 2021, below EPA’s legal limit of 80 ppb. In 2022, the latest year on file, it averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 10.8 ppb, in 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 10.2 ppb
Highest yearly average, 2020 to 2022 · 2022 average: 9.2 ppb · Forms or is added in treatment
Averaged by year, the highest was 10.2 ppb, in 2020, below EPA’s legal limit of 60 ppb. In 2022, the latest year on file, it averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 11.4 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
Lead, Action level 15 ppb · health goal zero; 90th percentile 2.0 ppb
90th percentile, 2023 to 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 2.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Nitrate, Legal limit 10 ppm; highest yearly average 1.3 ppm
Highest yearly average, 2020 to 2022 · 2022 average: 0.78 ppm · Comes from the source
Averaged by year, the highest was 1.3 ppm, in 2021, below EPA’s legal limit of 10 ppm. In 2022, the latest year on file, it averaged below the limit.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 1.0 ppb
Highest yearly average, 2022 · Comes from the source
Averaged by year, the highest was 1.0 ppb, in 2022, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That is the only year on file.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
PFBS, Health benchmark 2,000 ppt; highest 3.0 ppt
Highest sample, Sept. 23, 2025; found in 1 of 12 · Comes from the source
The highest sample was 3.0 ppt, below EPA’s health benchmark of 2,000 ppt. PFBS has no legal limit or health goal of its own.
What handles it
- NSF/ANSI 53 look for “Total PFAS Reduction”
EPA’s 2024 PFAS rule, compound by compoundAll six, found or not, and the Hazard Index, against the rule’s limits.
| PFAS | EPA’s limit | Result |
|---|---|---|
| PFOA | 4.0 ppt | Not foundNot found in any of 12 samples, below 4 ppt |
| PFOS | 4.0 ppt | Not foundNot found in any of 12 samples, below 4 ppt |
| PFHxS | 10 ppt | Not foundNot found in any of 12 samples, below 3 ppt |
| PFNA | 10 ppt | Not foundNot found in any of 12 samples, below 4 ppt |
| HFPO-DA (GenX) | 10 ppt | Not foundNot found in any of 12 samples, below 5 ppt |
| PFBS | Index only | Below EPA’s limits3.0 ppt highest, found in 1 of 12 samples. Details |
| Hazard IndexPFHxS, PFNA, HFPO-DA and PFBS together | 1 | Doesn’t applyDoesn’t apply: no sampling location found two or more of the four |
| Results from EPA’s UCMR 5 sampling. “Below” is the lab’s reporting level: a result under it reads as not found, which is not the same as zero. The limits are EPA’s 2024 rule, with compliance due from 2029; EPA has since proposed changes to some of them, explained on each compound’s page. PFBS has no limit of its own and counts only toward the Hazard Index, which adds up the four, each against EPA’s health-based level, from each sampling location’s average, as EPA’s UCMR 5 summary does. It counts only where two or more of the four were found, and is above the limit from 1.5. | ||
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFBA | 6.2 ppt | 2 of 12 | None covers it |
| PFHxA | 3.1 ppt | 1 of 12 | None covers it |
27 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
1 health-based violation since 2016 for the Surface Water Treatment Rule. It began April 1, 2023.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Surface Water Treatment Rule | Required treatment for surface water or groundwater was not met.EPA: Treatment Technique (SWTR and GWR) | April 1, 2023 to April 30, 2023 | Resolved |
Health-based violations only. 7 monitoring or reporting violations not shown.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Lead, Arsenic
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead, Arsenic
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Lead, Arsenic
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Lead, Arsenic
2 more filters
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Lead, Arsenic
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Every filter for these, those that cover both first
Disinfectant
Maynardville Water Dept reported chloramine at 1 of its 3 sampling points and chlorine without chloramine at 2, in its 2025 sampling for EPA. Which one reaches your tap can depend on where you live.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate and arsenic results here are Tennessee’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Maynardville Water Dept’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 12 to Dec. 9, 2025; CDC’s yearly averages for Tennessee cover 2020 to 2022.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Maynardville Water Dept’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 2.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Tennessee certifies closest to the area Maynardville Water Dept serves, or a kit by mail
The 3 labs Tennessee certifies closest to the area Maynardville Water Dept serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Eurofins Knoxville
Knoxville, TN · about 25 miles
Certified for metals, minerals and other inorganics, organic chemicals
Microbac - Knoxville Division
Maryville, TN · about 34 miles
Certified for bacteria, metals, minerals and other inorganics
Microbac Laboratories, Inc - Nashville
Maryville, TN · about 34 miles
Certified for bacteria
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Tennessee certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Tennessee’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and CDC’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportMaynardville Water Dept must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- CDC Environmental Public Health Tracking Network, yearly averages Tennessee supplied to CDC, 2020 to 2022, read Oct. 8, 2026. TapBuff’s comparisons with EPA’s limits are its own, not CDC’s or Tennessee’s.
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: TDEC, commercial laboratories certified for drinking water analysis, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TN0000442. Rebuilt from EPA data on Oct. 25, 2026.