Jellico Utilities Authority
EPA’s and CDC’s records have results for 37 contaminants in its water; 6 were found.
Serves 5,056 people · Surface water · Jellico, TN
- Serves
- 5,056 people
- Connections
- 2,124
- Water source
- Surface water
- Based in
- Jellico, TN
- County
- Campbell
- Owner
- Local government
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 1 health-based violation since 2016, resolved in EPA’s file.
Filters for arsenic and lead, if you want them lowerThe violationGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Feb. 14 to Nov. 21, 2023.
Lead and copper: EPA SDWIS monitoring periods ending 2013 to 2025.
Haloacetic acids (HAA5), total trihalomethanes (TTHM), arsenic and nitrate: Tennessee’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2022, with EPA’s 2012 to 2019 file for earlier years.
Fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from Jan. 21, 2015 to Nov. 7, 2017. Newer results are in the utility’s annual water quality report.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Below EPA’s limits, 6 results
Arsenic and lead have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 54.7 ppb
Highest yearly average, 2020 to 2022 · 2022 average: 34.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 54.7 ppb, in 2020, below EPA’s legal limit of 60 ppb. In 2022, the latest year on file, it averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 39.5 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 52.1 ppb
Highest yearly average, 2020 to 2022 · 2022 average: 42.3 ppb · Forms or is added in treatment
Averaged by year, the highest was 52.1 ppb, in 2020, below EPA’s legal limit of 80 ppb. In 2022, the latest year on file, it averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 32 ppb, in 2015.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 4.0 ppb
Highest yearly average, 2020 · Comes from the source
Averaged by year, the highest was 4.0 ppb, in 2020, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That is the only year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 1.6 ppb, in 2016.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.67 ppm
Highest yearly average, 2015 to 2017 · 2017, one sample: 0.6 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.67 ppm, in 2016, below EPA’s legal limit of 4.0 ppm. In 2017, the latest year on file, its one sample was below the limit.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Lead, Action level 15 ppb · health goal zero; 90th percentile 0.9 ppb
90th percentile, 2023 to 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 0.9 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Nitrate, Legal limit 10 ppm; highest yearly average 0.44 ppm
Highest yearly average, 2022 · Comes from the source
Averaged by year, the highest was 0.44 ppm, in 2022, below EPA’s legal limit of 10 ppm. That is the only year on file.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest sample of 0.17 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Chromium (total)
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
1 health-based violation since 2016 for the Interim Enhanced Surface Water Treatment Rule. It began Feb. 1, 2018.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | Feb. 1, 2018 to Feb. 28, 2018 | Resolved |
Health-based violations only. 89 monitoring or reporting violations not shown.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Arsenic, Lead
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction
For: Arsenic, Lead
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Arsenic, Lead
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Arsenic, Lead
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Arsenic, Lead
2 more filters
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
Five years: $2,917, household of 3, cartridges included
Certified for: Arsenic, Lead
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Every filter for these, those that cover both first
Disinfectant
Jellico Utilities Authority reported adding chloramine before water enters its pipes, at its one sampling point, in its 2023 sampling for EPA. It also reported permanganate.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), arsenic and nitrate results here are Tennessee’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Jellico Utilities Authority’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 14 to Nov. 21, 2023; CDC’s yearly averages for Tennessee cover 2020 to 2022; EPA’s compliance samples are from Jan. 21, 2015 to Nov. 7, 2017.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Jellico Utilities Authority’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0.9 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Tennessee certifies closest to the area Jellico Utilities Authority serves, or a kit by mail
The 3 labs Tennessee certifies closest to the area Jellico Utilities Authority serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Assured Bio Labs, LLC
Oak Ridge, TN · about 39 miles
Certified for bacteria
DOE Y-12 CNS National Security Complex
Oak Ridge, TN · about 39 miles
Certified for metals, minerals and other inorganics, disinfection byproducts, radioactivity
Eberline Analytical Oak Ridge
Oak Ridge, TN · about 39 miles
Certified for radioactivity
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Tennessee certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Tennessee’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s and CDC’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportJellico Utilities Authority must send you a water quality report every year. It covers contaminants this page does not show, and has newer results than EPA’s national file for the ones here that come from it.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- CDC Environmental Public Health Tracking Network, yearly averages Tennessee supplied to CDC, 2020 to 2022, read Oct. 8, 2026. TapBuff’s comparisons with EPA’s limits are its own, not CDC’s or Tennessee’s.
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: TDEC, commercial laboratories certified for drinking water analysis, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID TN0000330. Rebuilt from EPA data on Oct. 25, 2026.
Towns it serves
Nearby
- Lafollette Utilities Board27,984
- Caryville - Jacksboro Utilities Commission11,079
- Deerfield Water System, LLC1,299
- Caryville - Jacksboro Utilities #2162
- Oneida Water and Sewer CommissionScott County · 16 mi11,600
- Huntsville Utility DistrictScott County · 21 mi12,516