EPA’s records have results for 33 contaminants in its water; 4 were found.

Serves 5,610 people · Surface water bought from another system · Rosebud, SD

Serves
5,610 people
Connections
888
Water source
Surface water bought from another system
Based in
Rosebud, SD
Owner
Native American
The 4 ZIP codes it serves

57555, 57560, 57579, 57585

The short answer

None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. 1 health-based violation since 2016, with no fix on record in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

Filters for lead, if you want it lower⁠The violation⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from April 3 to Dec. 6, 2023.

Lead and copper: EPA SDWIS monitoring periods ending 2015 to 2025.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): EPA’s compliance monitoring file, samples taken from Nov. 4, 2013 to Nov. 18, 2019. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Above EPA’s health benchmark, 1 result

Lithium

Comes from the source

Above EPA’s health benchmark

69.6 ppb

Highest sample, Dec. 6, 2023; found in 4 of 4

The highest sample was 69.6 ppb, about 7 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.

What handles it

No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.

How to read your utility’s report

Below EPA’s limits, 3 results

Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 48.1 ppb

Highest yearly average, 2013 to 2019 · 2019 average: 22.7 ppb · Forms or is added in treatment

Averaged by year, the highest was 48.1 ppb, in 2015, below EPA’s legal limit of 80 ppb. Its highest single sample was 59.7 ppb. In 2019, the latest year on file, its eight samples averaged below the limit.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 31 ppb

Highest yearly average, 2013 to 2019 · 2019 average: 11.1 ppb · Forms or is added in treatment

Averaged by year, the highest was 31 ppb, in 2014, below EPA’s legal limit of 60 ppb. Its highest single sample was 37.3 ppb. In 2019, the latest year on file, its eight samples averaged below the limit.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.1 ppb

90th percentile, 2025 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 1.1 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Utilities above EPA’s PFAS limits, state by state⁠
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

1 health-based violation since 2016 for the Lead and Copper Rule Revisions. It began Oct. 17, 2024, and it has no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024No fix on recordEPA: unaddressed

Health-based violations only. 5 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for lead, ranked⁠

Disinfectant

Sicangu Mni Wiconi Rural Water System reported adding chloramine before water enters its pipes, at its one sampling point, in its 2023 sampling for EPA.

What that means

Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Newer results, and everything else. Nitrate, arsenic, fluoride, chromium, uranium and disinfection byproduct results here come from EPA’s national compliance file, which ends in 2019. Sicangu Mni Wiconi Rural Water System’s own annual report, which it must send you every year, has newer results and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from April 3 to Dec. 6, 2023; EPA’s compliance samples are from Nov. 4, 2013 to Nov. 18, 2019.

Testing your own tap

Sicangu Mni Wiconi Rural Water System’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab South Dakota certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Sicangu Mni Wiconi Rural Water System’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 1.1 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Sicangu Mni Wiconi Rural Water System’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
Labs South Dakota certifies, or a kit by mail

No lab South Dakota certifies is within 75 miles of the area Sicangu Mni Wiconi Rural Water System serves on the state’s list. Some take samples by mail; the state’s page lists them all.

All 16 certified labs for South Dakota⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that South Dakota certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against South Dakota’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID 084690516. Rebuilt from EPA data on Oct. 25, 2026.