Skip to content
TapBuff

Sjwd Middle Tyger WTP

EPA’s and South Carolina’s records have results for 38 contaminants in its water; 3 were found.

Serves 89,531 people · Surface water · Lyman, SC

Serves
89,531 people
Connections
36,895
Water source
Surface water
Based in
Lyman, SC
County
Spartanburg
Owner
Local government
The 11 ZIP codes it serves

29301, 29322, 29334, 29349, 29365, 29369, 29375, 29377, 29385, 29388, 29651

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Jan. 7 to Oct. 7, 2025.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic, chromium (total) and fluoride: South Carolina’s own results, samples taken from Jan. 28, 2020 to July 28, 2026, with EPA’s 2012 to 2019 file for earlier years.

Uranium: EPA’s compliance monitoring file, samples taken from Feb. 12, 2013 to April 3, 2013. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 3 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 47.7 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 38.5 ppb · Forms or is added in treatment

Averaged by year, the highest was 47.7 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 88.2 ppb. In 2026, the latest year on file, its 24 samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 52.5 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 34.4 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 27.5 ppb · Forms or is added in treatment

Averaged by year, the highest was 34.4 ppb, in 2023, below EPA’s legal limit of 60 ppb. Its highest single sample was 71.8 ppb. In 2026, the latest year on file, its 24 samples averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 30.3 ppb, in 2017.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Nitrate, Legal limit 10 ppm; highest 0.34 ppm

Highest sample; found in 14 of 14 · 2026, one sample: 0.18 ppm · Comes from the source

The highest sample, in 2022, was 0.34 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.43 ppm, in 2014.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
South Carolina utilities above EPA’s PFAS limits⁠
35 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Fluoride
  • Lead
  • Uranium

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Disinfectant

Sjwd Middle Tyger WTP reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic, chromium (total) and fluoride results here are South Carolina’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium comes from EPA’s file alone, which ends in 2019. Sjwd Middle Tyger WTP’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 7 to Oct. 7, 2025; South Carolina’s results run from Jan. 28, 2020 to July 28, 2026; EPA’s compliance samples are from Feb. 12 to April 3, 2013.

Testing your own tap

Sjwd Middle Tyger WTP’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab South Carolina certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Sjwd Middle Tyger WTP’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs South Carolina certifies closest to the area Sjwd Middle Tyger WTP serves, or a kit by mail

The 3 labs South Carolina certifies closest to the area Sjwd Middle Tyger WTP serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Alliance Technical Group LLC - Greenville

    Greenville, SC · about 17 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (864) 232-1556

  • L&L Environmental Ware Shoals

    Ware Shoals, SC · about 39 miles

    Certified for bacteria

    (864) 456-2696

  • International Product Assurance Laboratories

    Anderson, SC · about 47 miles

    Certified for lead and copper, metals

    (864) 784-9883

All 36 certified labs for South Carolina⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that South Carolina certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against South Carolina’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID SC4220006. Rebuilt from EPA data on Oct. 25, 2026.