Skip to content
TapBuff

Smithfield Water Supply Board

EPA’s and Rhode Island’s records have results for 33 contaminants in its water; 2 were found.

Serves 9,460 people · Surface water bought from another system · Smithfield, RI

Serves
9,460 people
Connections
1,689
Water source
Surface water bought from another system
Based in
Smithfield, RI
County
Providence
Owner
Local government
The 3 ZIP codes it serves

02904, 02911, 02917

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 3 health-based violations since 2016, all resolved in EPA’s file.

The 3 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Feb. 18 to Nov. 17, 2025.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Rhode Island’s own results, samples taken from Feb. 12, 2020 to Aug. 12, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 59.7 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 46 ppb · Forms or is added in treatment

Averaged by year, the highest was 59.7 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 73 ppb. In 2026, the latest year on file, its six samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 74.6 ppb, in 2017, and EPA recorded violations in 2017 and 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 18.8 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 14.9 ppb · Forms or is added in treatment

Averaged by year, the highest was 18.8 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 23.2 ppb. In 2026, the latest year on file, its six samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 22.8 ppb, in 2014.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Rhode Island utilities above EPA’s PFAS limits⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

3 health-based violations since 2016, all for TTHM. The latest began April 1, 2018.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2018 to June 30, 2018, 81 ppbResolved
Jan. 1, 2018 to March 31, 2018, 81 ppbResolved
Oct. 1, 2017 to Dec. 31, 2017, 81 ppbResolved

Health-based violations only. 2 monitoring or reporting violations not shown.

Disinfectant

Smithfield Water Supply Board reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Rhode Island’s own from 2020 on, with EPA’s national file for 2012 to 2019. Smithfield Water Supply Board’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 18 to Nov. 17, 2025; Rhode Island’s results run from Feb. 12, 2020 to Aug. 12, 2026.

Testing your own tap

Smithfield Water Supply Board’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Rhode Island certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Smithfield Water Supply Board’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Rhode Island certifies closest to the area Smithfield Water Supply Board serves, or a kit by mail

The 3 labs Rhode Island certifies closest to the area Smithfield Water Supply Board serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

All 6 certified labs for Rhode Island⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Rhode Island certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Rhode Island’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID RI1615616. Rebuilt from EPA data on Oct. 25, 2026.