Skip to content
TapBuff

Cne - New London Turnpike Entry Point

EPA’s and Rhode Island’s records have results for 33 contaminants in its water; 2 were found.

Serves 9,999 people · Groundwater bought from another system · Coventry, RI

Serves
9,999 people
Connections
97
Water source
Groundwater bought from another system
Based in
Coventry, RI
County
Kent
Owner
Private
The 2 ZIP codes it serves

02816, 02905

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 3 health-based violations since 2016, 1 with no fix on record in EPA’s file.

The 3 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from May 29 to Sept. 22, 2025.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Rhode Island’s own results, samples taken from Feb. 21, 2020 to Aug. 6, 2026, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 68.2 ppb

Highest yearly average, 2020 to 2026 · Forms or is added in treatment

Averaged by year, the highest was 68.2 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 86.5 ppb. That was also the latest year on file. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 79.8 ppb, in 2017, and EPA recorded violations in 2017 and 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 19.4 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 18.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 19.4 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 25.4 ppb. In 2026, the latest year on file, its six samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 20.8 ppb, in 2017.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Rhode Island utilities above EPA’s PFAS limits⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

3 health-based violations since 2016, 2 for TTHM and 1 for the Revised Total Coliform Rule. The latest began Jan. 1, 2018, and 1 has no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 2018, 81 ppbResolved
Revised Total Coliform RuleE. coli was confirmed in the water system.EPA: Maximum Contaminant Level Violation, E. coli (RTCR)Dec. 1, 2017 to Dec. 31, 2017No fix on recordEPA: archived
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 2017, 81 ppbResolved

Health-based violations only. 18 monitoring or reporting violations not shown.

Disinfectant

Cne - New London Turnpike Entry Point reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 sampling for EPA. It also reported another disinfectant.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Rhode Island’s own from 2020 on, with EPA’s national file for 2012 to 2019. Cne - New London Turnpike Entry Point’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from May 29 to Sept. 22, 2025; Rhode Island’s results run from Feb. 21, 2020 to Aug. 6, 2026.

Testing your own tap

Cne - New London Turnpike Entry Point’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Rhode Island certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Cne - New London Turnpike Entry Point’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Rhode Island certifies closest to the area Cne - New London Turnpike Entry Point serves, or a kit by mail

The 3 labs Rhode Island certifies closest to the area Cne - New London Turnpike Entry Point serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

All 6 certified labs for Rhode Island⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Rhode Island certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Rhode Island’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID RI2980453. Rebuilt from EPA data on Oct. 25, 2026.