Cotto Laurel
EPA’s records have results for 31 contaminants in its water; 1 was found.
Serves 12,979 people · Surface water · Ponce, PR
- Serves
- 12,979 people
- Connections
- 4,861
- Water source
- Surface water
- Based in
- Ponce, PR
- County
- Ponce Municipio
- Owner
- Local government
The ZIP code it serves
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium, plus lead and copper, not everything. 37 health-based violations since 2016, 2 with no fix on record in EPA’s file.
Filters for lead, if you want it lowerThe 37 violationsGot a notice? What it means
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Nov. 8, 2024 to Aug. 7, 2025.
Lead and copper: EPA SDWIS monitoring periods ending 2000 to 2015.
What the lines mean
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Below EPA’s limits, 1 result
Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Lead, Action level 15 ppb · health goal zero; 90th percentile 6.0 ppb
90th percentile, 2015 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 6.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
30 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
37 health-based violations since 2016, 14 for the Interim Enhanced Surface Water Treatment Rule, 10 for total organic carbon, 8 for TTHM and 5 for total Haloacetic Acids (HAA5). The latest began Oct. 1, 2025, and 2 have no fix on record in EPA’s file.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Interim Enhanced Surface Water Treatment Rule | One cloudiness reading was above the maximum allowed.EPA: Single Turbidity Exceed (Enhanced SWTR) | Oct. 1, 2025 to Oct. 31, 2025 | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | Oct. 1, 2025 to Oct. 31, 2025 | Resolved |
| Sept. 1, 2023 to Sept. 30, 2023 | Resolved | ||
| Aug. 1, 2023 to Aug. 31, 2023 | Resolved | ||
| Interim Enhanced Surface Water Treatment Rule | One cloudiness reading was above the maximum allowed.EPA: Single Turbidity Exceed (Enhanced SWTR) | Aug. 1, 2021 to Aug. 31, 2021 | Resolved |
The other 32, back to 2016
| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | Aug. 1, 2021 to Aug. 31, 2021 | Resolved |
| Interim Enhanced Surface Water Treatment Rule | One cloudiness reading was above the maximum allowed.EPA: Single Turbidity Exceed (Enhanced SWTR) | July 1, 2021 to July 31, 2021 | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | July 1, 2021 to July 31, 2021 | Resolved |
| July 1, 2021 to July 31, 2021 | Resolved | ||
| Nov. 1, 2020 to Nov. 30, 2020 | Resolved | ||
| Interim Enhanced Surface Water Treatment Rule | One cloudiness reading was above the maximum allowed.EPA: Single Turbidity Exceed (Enhanced SWTR) | Oct. 1, 2020 to Oct. 31, 2020 | Resolved |
| Interim Enhanced Surface Water Treatment Rule | Too many readings in a month showed cloudiness above the filtration standard.EPA: Monthly Turbidity Exceed (Enhanced SWTR) | Oct. 1, 2020 to Oct. 31, 2020 | No fix on recordEPA: archived |
| Oct. 1, 2020 to Oct. 31, 2020 | No fix on recordEPA: archived | ||
| Oct. 1, 2020 to Oct. 31, 2020 | Resolved | ||
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2018 to Dec. 31, 2018, 81 ppb | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2018 to Dec. 31, 2018, 66 ppb | Resolved |
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | April 1, 2018 to June 30, 2018 | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2018 to June 30, 2018, 98 ppb | Resolved |
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | April 1, 2018 to June 30, 2018, 95 ppb | Resolved |
| Jan. 1, 2018 to March 31, 2018, 93 ppb | Resolved | ||
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2018 to March 31, 2018, 115 ppb | Resolved |
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | July 1, 2017 to Sept. 30, 2017 | Resolved |
| April 1, 2017 to June 30, 2017 | Resolved | ||
| April 1, 2017 to June 30, 2017 | Resolved | ||
| Jan. 1, 2017 to March 31, 2017 | Resolved | ||
| Jan. 1, 2017 to March 31, 2017 | Resolved | ||
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2017 to March 31, 2017, 99 ppb | Resolved |
| Oct. 1, 2016 to Dec. 31, 2016, 95 ppb | Resolved | ||
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Oct. 1, 2016 to Dec. 31, 2016, 65 ppb | Resolved |
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | July 1, 2016 to Sept. 30, 2016 | Resolved |
| July 1, 2016 to Sept. 30, 2016 | Resolved | ||
| Total Haloacetic Acids (HAA5) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2016 to Sept. 30, 2016, 64 ppb | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2016 to Sept. 30, 2016, 92 ppb | Resolved |
| April 1, 2016 to June 30, 2016, 98 ppb | Resolved | ||
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | Jan. 1, 2016 to March 31, 2016 | Resolved |
| TTHM | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | Jan. 1, 2016 to March 31, 2016, 101 ppb | Resolved |
| Total organic carbon | Not enough organic matter was removed. It reacts with disinfectant to form byproducts.EPA: Treatment Technique Precursor Removal | Jan. 1, 2016 to March 31, 2016 | Resolved |
Health-based violations only. 43 monitoring or reporting violations not shown.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claim: Lead Reduction
For: Lead
- NSF/ANSI 58
Claim: Lead Reduction
For: Lead
At the tap, or for the whole house?
These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Express Water StreamLine Direct Connect System (USC001)
Under-sink carbon
Five years: $527, household of 3, cartridges included
Certified for: Lead
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead
Frizzlife SK99 Under Sink Water Filter
Under-sink carbon
Five years: $590, household of 3, cartridges included
Certified for: Lead
2 more filters
Bluevua RO100ROPOT-Lite Countertop Reverse Osmosis System
Countertop reverse osmosis
Five years: $805, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Lead
Brondell Coral UC300 Under Sink Water Filtration System
Under-sink carbon
Five years: $900, household of 3, cartridges included
Certified for: Lead
Disinfectant
Cotto Laurel reported disinfecting with chlorine, not chloramine, at all 3 of its sampling points, in its 2024 to 2025 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Newer results, and everything else. Nitrate, arsenic, fluoride, chromium, uranium and disinfection byproduct results here come from EPA’s national compliance file, which ends in 2019. Cotto Laurel’s own annual report, which it must send you every year, has newer results and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Nov. 8, 2024 to Aug. 7, 2025.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Cotto Laurel’s latest lead sampling in EPA’s records, 2015, had a 90th percentile of 6.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
Labs Puerto Rico certifies, or a kit by mail
No lab Puerto Rico certifies is within 75 miles of the area Cotto Laurel serves on the state’s list. Some take samples by mail; the state’s page lists them all.
All 12 certified labs for Puerto RicoOr test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Puerto Rico certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Puerto Rico’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Nothing here is above an EPA limit or health benchmarkIn EPA’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportCotto Laurel must send you a water quality report every year. It has newer results than EPA’s national file, which ends in 2019.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID PR0004524. Rebuilt from EPA data on Oct. 25, 2026.