Skip to content
TapBuff

Rogers Co RWD # 4

EPA’s and Oklahoma’s records have results for 38 contaminants in its water; 5 were found.

In the name, RWD means rural water district.

Serves 7,725 people · Surface water · Oologah, OK

Serves
7,725 people
Connections
3,486
Water source
Surface water
Based in
Oologah, OK
County
Rogers
Owner
Local government
The 3 ZIP codes it serves

74053, 74061, 74080

The short answer

EPA recorded a violation of the legal limit for haloacetic acids (HAA5) here in 2022. In 2026, the latest year on file, it averaged 20.3 ppb, below the limit. 2 health-based violations since 2016, both resolved in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

The 2 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from March 5 to Dec. 16, 2024.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride, arsenic and chromium (total): Oklahoma’s own results, samples taken from Feb. 6, 2020 to Aug. 12, 2026, with EPA’s 2012 to 2019 file for earlier years.

Uranium: EPA’s compliance monitoring file, samples taken from May 3, 2017 to May 3, 2017. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFBA at 5.6 ppt: see it below.

A legal-limit violation on record, below the limit in the latest year, 1 result

Haloacetic acids (HAA5)

Forms or is added in treatment

Violation on record (2022)

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days.

51 ppb

Highest yearly average, 2020 to 2026

2026 average: 20.3 ppb

Averaged by year, the highest was 51 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 71.2 ppb. In 2026, the latest year on file, its six samples averaged below the limit. EPA recorded a violation for haloacetic acids (HAA5) at this utility in 2022.

How it’s judged

EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 61 ppb, in 2013.

What handles it

No certification claim covers this compound yet.

Below EPA’s limits, 3 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 54.1 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 42.8 ppb · Forms or is added in treatment

Averaged by year, the highest was 54.1 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 89.3 ppb. In 2026, the latest year on file, its six samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 80 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Nitrate, Legal limit 10 ppm; highest 0.36 ppm

Highest sample; found in 1 of 6 · 2025: not found · Comes from the source

The highest sample, in 2024, was 0.36 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in its one sample.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.49 ppm, in 2017.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.14 ppm

Highest yearly average, 2020 · Forms or is added in treatment

Averaged by year, the highest was 0.14 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. That is the only year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.73 ppm, in 2012.

What handles it

About fluoride
Oklahoma utilities above EPA’s PFAS limits⁠

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

PFAS found with no federal limit
CompoundHighest sampleFound inCertification claim
PFBA5.6 ppt1 of 4None covers it
33 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Lead
  • Uranium

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

2 health-based violations since 2016, 1 for the Lead and Copper Rule Revisions and 1 for total Haloacetic Acids (HAA5). The latest began Oct. 17, 2024.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024Resolved
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2022 to March 31, 2022, 62 ppbResolved

Health-based violations only. 13 monitoring or reporting violations not shown.

Disinfectant

Rogers Co RWD # 4 reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2024 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate, fluoride, arsenic and chromium (total) results here are Oklahoma’s own from 2020 on, with EPA’s national file for 2012 to 2019. Uranium comes from EPA’s file alone, which ends in 2019. Rogers Co RWD # 4’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 5 to Dec. 16, 2024; Oklahoma’s results run from Feb. 6, 2020 to Aug. 12, 2026; EPA’s compliance samples are from May 3 to 3, 2017.

Testing your own tap

Rogers Co RWD # 4’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Oklahoma certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Rogers Co RWD # 4’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Rogers Co RWD # 4’s results flag: haloacetic acids (HAA5). It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
Labs Oklahoma certifies, or a kit by mail

TapBuff hasn’t read Oklahoma’s list of certified labs yet. The national page links every state’s own list.

Certified labs, state by state⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Oklahoma certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Oklahoma’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID OK1021506. Rebuilt from EPA data on Oct. 25, 2026.