TapBuffZIP
Menu

Nichols Hills water quality report, rewritten

Serves
4,020
Connections
1,924
Water source
Groundwater
Based in
Nichols Hills, OK
County
Oklahoma
Owner
Local government
The ZIP code it serves

73116

PWSID OK20055012026 edition · EPA data

Read this first

  • Lithium (above EPA’s health benchmark) was found in four of 4 samples, highest 17 ppb. Above EPA’s health reference level of 10 ppb, a screening level rather than an enforceable limit.

3 health-based violations since 2016. Details are below.

What was found

Highlighted: above the health goal, or EPA’s health benchmark where there is no goal. Circled: above the legal limit in at least one sample, or the action level. Every scale puts that line at its middle.

17ppb

Highest of 4 samples; found in four

Above EPA’s health reference level of 10 ppb, a screening level rather than an enforceable limit.

What handles it

No certification claim covers this compound yet.

EPA UCMR 5, samples taken from May 22, 2024 to Dec. 10, 2025. Each blue tick is one sample where it was found.

Tested and not found

Below EPA’s minimum reporting level in every sample taken from May 22, 2024 to Dec. 10, 2025. Not found means not measured above that level, which is not the same as zero.

All 30 compounds tested and not found
  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lead
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Resolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 20160.013 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2016 to March 31, 20160.013 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 69 monitoring or reporting violations not shown.

What this report cannot tell you

  • Levels of everything else. Federal bulk data carries results for PFAS, lithium, lead and copper, and violations for the rest. Nitrate, arsenic, disinfection byproducts and other levels are in Nichols Hills’s own annual report, which it must send you every year.
  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
  • Anything after the latest data. SDWIS data is from 2026 Q2; UCMR 5 samples are from May 22, 2024 to Dec. 10, 2025.

What to do next

  1. Read up on Lithium

    What each one does to health, where it comes from, and the certification claim that addresses it.

    About Lithium
  2. Get the utility’s own report

    Nichols Hills must send you a water quality report every year. It lists nitrate, arsenic and byproduct levels this page cannot.

    How to read it
  3. Test your own tap for lead

    Your service line, solder and fixtures decide the lead at your faucet, not the utility’s average.

    Lead in your water: what to do
  4. Decide if you want a filter at all

    A filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.

    NSF/ANSI standards, decoded