EPA’s and Oklahoma’s records have results for 38 contaminants in its water; 5 were found.

In the name, RWD means rural water district.

Serves 4,800 people · Groundwater · Sulphur, OK

Serves
4,800 people
Connections
2,235
Water source
Groundwater
Based in
Sulphur, OK
County
Murray
Owner
Local government
The 5 ZIP codes it serves

73030, 73086, 73098, 74865, 74872

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 1 health-based violation since 2016, resolved in EPA’s file.

Filters for lead and uranium, if you want them lower⁠The violation⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Jan. 11 to July 24, 2023.

Lead and copper: EPA SDWIS monitoring periods ending 2003 to 2024.

Nitrate, total trihalomethanes (TTHM), uranium, fluoride, arsenic, chromium (total) and haloacetic acids (HAA5): Oklahoma’s own results, samples taken from March 11, 2020 to Aug. 28, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 5 results

Lead and uranium have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Lead, Action level 15 ppb · health goal zero; 90th percentile 2.8 ppb

90th percentile, 2022 to 2024 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 2.8 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Nitrate, Legal limit 10 ppm; highest 0.83 ppm

Highest sample; found in 7 of 7 · 2026, one sample: 0.74 ppm · Comes from the source

The highest sample, in 2023, was 0.83 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.74 ppm, in 2019.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 3.4 ppb

Highest yearly average, 2020 to 2026 · 2026: not found · Forms or is added in treatment

Averaged by year, the highest was 3.4 ppb, in 2024, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, it wasn’t found in its one sample.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 3.7 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 1.0 ppb

Highest yearly average, 2021 · Comes from the source

Averaged by year, the highest was 1.0 ppb, in 2021, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That is the only year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 2.0 ppb, in 2015.

What handles it

About uranium
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.094 ppm

Highest yearly average, 2024 · Forms or is added in treatment

Averaged by year, the highest was 0.094 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. That is the only year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.11 ppm, in 2015.

What handles it

About fluoride
Oklahoma utilities above EPA’s PFAS limits⁠
33 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Haloacetic acids (HAA5)

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

1 health-based violation since 2016 for the Lead and Copper Rule Revisions. It began Oct. 17, 2024.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024Resolved

Health-based violations only. 1 monitoring or reporting violation not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter for these, those that cover both first⁠

The best water filters for lead, ranked⁠

Disinfectant

Murray Co RWD # 1 reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Nitrate, total trihalomethanes (TTHM), uranium, fluoride, arsenic, chromium (total) and haloacetic acids (HAA5) results here are Oklahoma’s own from 2020 on, with EPA’s national file for 2012 to 2019. Murray Co RWD # 1’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 11 to July 24, 2023; Oklahoma’s results run from March 11, 2020 to Aug. 28, 2026.

Testing your own tap

Murray Co RWD # 1’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Oklahoma certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Murray Co RWD # 1’s latest lead sampling in EPA’s records, 2022 to 2024, had a 90th percentile of 2.8 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
Labs Oklahoma certifies, or a kit by mail

TapBuff hasn’t read Oklahoma’s list of certified labs yet. The national page links every state’s own list.

Certified labs, state by state⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Oklahoma certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Oklahoma’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID OK2005012. Rebuilt from EPA data on Oct. 25, 2026.