Skip to content
TapBuff

Van Wert City

EPA’s and Ohio’s records have results for 37 contaminants in its water; 6 were found.

Serves 10,846 people · Surface water · Van Wert, OH

Serves
10,846 people
Connections
5,000
Water source
Surface water
Based in
Van Wert, OH
County
Van Wert
Owner
Local government
The ZIP code it serves

45891

The short answer

EPA recorded violations of the legal limit for total trihalomethanes (TTHM) here in four years from 2022 to 2026. 8 health-based violations since 2016, 1 with no fix on record in EPA’s file.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠The 8 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from March 3 to Dec. 3, 2025.

Lead and copper: EPA SDWIS monitoring periods ending 2013 to 2026. Copper at 83 mg/L (2004) is left out of this report: it is one of the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, fluoride, arsenic and chromium (total): Ohio’s own results, samples taken from Jan. 2, 2020 to Dec. 3, 2025, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

A legal-limit violation on record, below the limit in the latest year, 1 result

Total trihalomethanes (TTHM)

Forms or is added in treatment

Violation on record (2026)

What it means for you. EPA’s concern is long-term exposure, years of drinking it, not an immediate risk to health. A violation like this calls for a notice to customers within 30 days. A filter certified for it, at the tap you drink from, reduces it.

70.9 ppb

Highest yearly average, 2020 to 2025

2025 average: 64.1 ppb

Averaged by year, the highest was 70.9 ppb, in 2022, below EPA’s legal limit of 80 ppb. Its highest single sample was 109 ppb. In 2025, the latest year on file, its 16 samples averaged below the limit. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2022, 2023, 2025 and 2026.

How it’s judged

EPA judges this limit at each sampling point, so a violation can be on record in a year whose average is below it.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 60 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Below EPA’s limits, 5 results

Arsenic and lead have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 30.2 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 22.1 ppb · Forms or is added in treatment

Averaged by year, the highest was 30.2 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 51.9 ppb. In 2025, the latest year on file, its 16 samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 35.1 ppb, in 2012.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Nitrate, Legal limit 10 ppm; highest 4.1 ppm

Highest sample; found in 61 of 71 · 2025 average: 1.5 ppm · Comes from the source

The highest sample, in 2020, was 4.1 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its 12 samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 6.0 ppm, in 2016.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Fluoride, Legal limit 4.0 ppm; highest yearly average 1.2 ppm

Highest yearly average, 2020 to 2025 · Forms or is added in treatment

Averaged by year, the highest was 1.2 ppm, in 2025, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 1.2 ppm, in 2012.

What handles it

About fluoride
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.9 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 0.7 ppb · Comes from the source

Averaged by year, the highest was 0.9 ppb, in 2023, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. In 2025, the latest year on file, its two samples averaged below the limit.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
About arsenic
Lead, Action level 15 ppb · health goal zero; 90th percentile 0.5 ppb

90th percentile, 2026 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 0.5 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Ohio utilities above EPA’s PFAS limits⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Chromium (total)

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

8 health-based violations since 2016, all for TTHM. The latest began April 1, 2026, and 1 has no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2026 to June 30, 2026, 83 ppbNo fix on recordEPA: archived
April 1, 2025 to June 30, 2025, 82 ppbResolved
Jan. 1, 2025 to March 31, 2025, 84 ppbResolved
July 1, 2023 to Sept. 30, 2023, 83 ppbResolved
April 1, 2023 to June 30, 2023, 85 ppbResolved
The other 3, back to 2022
Earlier health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2023 to March 31, 2023, 94 ppbResolved
Oct. 1, 2022 to Dec. 31, 2022, 86 ppbResolved
July 1, 2022 to Sept. 30, 2022, 83 ppbResolved

Health-based violations only. 6 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Arsenic, Lead

    Other claims that cover it: VOC Reduction; Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Arsenic, Lead

    Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for TTHM, ranked⁠

The best reverse osmosis systems, ranked⁠

The best water filters for lead, ranked⁠

Disinfectant

Van Wert City reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 sampling for EPA. It also reported permanganate.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, fluoride, arsenic and chromium (total) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Van Wert City’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 3 to Dec. 3, 2025; Ohio’s results run from Jan. 2, 2020 to Dec. 3, 2025.

Testing your own tap

Van Wert City’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Van Wert City’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 0.5 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Van Wert City’s results flag: total trihalomethanes (TTHM). It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Ohio certifies closest to the area Van Wert City serves, or a kit by mail

The 3 labs Ohio certifies closest to the area Van Wert City serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins DW and WW Central - Lima

    Lima, OH · about 24 miles

    Certified for bacteria

    (419) 223-1362

  • Kleinfelder Water Technologies Laboratory

    McClure, OH · about 47 miles

    Certified for bacteria

    (419) 748-7438

  • Logan County Health District Laboratory

    Bellefontaine, OH · about 55 miles

    Certified for bacteria

    (937) 592-9040

All 76 certified labs for Ohio⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Ohio certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Ohio’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID OH8100611. Rebuilt from EPA data on Oct. 25, 2026.