Skip to content
TapBuff

Utica Village PWS

What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
2,235 people
Connections
889
Water source
Groundwater
Based in
Utica, OH
County
Licking
Owner
Local government
The ZIP code it serves

43080

The short answer

2 results are above the health goal. The worst: Lead, above the health goal. 1 health-based violation since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2010 to 2025. Copper at 124 mg/L (2005) is left out of this report: it is one of the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate and chromium (total): Ohio’s own results, samples taken from Aug. 12, 2020 to July 17, 2025, with EPA’s 2012 to 2019 file for earlier years.

Above the health goal2

Lead

Comes from pipes, often your own

Above the health goal

2.0ppb

90th percentile, 2025

In the latest period, 9 in 10 homes sampled were at or below 2.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the health goal

1.2ppb

Highest yearly average, 2021 to 2024

2024: not found

Averaged by year, the highest was 1.2 ppb, in 2021: below EPA’s legal limit of 10 ppb, but above its health goal of zero. In 2024, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits4

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

20.1ppb

Highest yearly average, 2020 to 2025

2025 average: 8.2 ppb

Averaged by year, the highest was 20.1 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 27.5 ppb. In 2025, the latest year on file, its two samples averaged 8.2 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 13.8 ppb, in 2012.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

10.8ppb

Highest yearly average, 2020 to 2025

2025: not found

Averaged by year, the highest was 10.8 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 15.6 ppb. In 2025, the latest year on file, it wasn’t found in any of its two samples.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.35ppm

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.35 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.5 ppm, in 2015.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.44ppm

Highest sample; found in 3 of 6

2025: not found

The highest sample, in 2022, was 0.44 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

The best reverse osmosis systems, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 10 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate and chromium (total) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Utica Village PWS’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from Aug. 12, 2020 to July 17, 2025.

Testing your own tap

Utica Village PWS’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

The 3 labs Ohio certifies closest to the area Utica Village PWS serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Ohio Department of Agriculture Consumer Protection Laboratory

    Reynoldsburg, OH · about 27 miles

    Certified for bacteria

    (614) 728-6230

  • Coshocton Environmental Testing, LLC

    Coshocton, OH · about 29 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (740) 622-3328

  • Benchmark Environmental Labs, Inc.

    Columbus, OH · about 34 miles

    Certified for bacteria

    (614) 267-4588

All 76 certified labs for Ohio

Sources