Skip to content
TapBuff

Stratton PWS

What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
320 people
Connections
188
Water source
Groundwater
Based in
Wellsville, OH
County
Jefferson
Owner
Local government
The 2 ZIP codes it serves

43926, 43961

The short answer

Nothing in EPA’s and Ohio’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 1 health-based violation since 2016.

What was found

Total trihalomethanes (TTHM), fluoride, nitrate, arsenic, chromium (total) and haloacetic acids (HAA5): Ohio’s own results, samples taken from Jan. 14, 2020 to July 8, 2025, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits3

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

11.2ppb

Highest yearly average, 2020 to 2025

2025, one sample: 4.0 ppb

Averaged by year, the highest was 11.2 ppb, in 2022, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, its one sample was 4.0 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 22.7 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.45ppm

Highest yearly average, 2021 to 2024

Averaged by year, the highest was 0.45 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.46 ppm, in 2015.

What handles it

Nitrate

Comes from the source

Below EPA’s limits

0.4ppm

Highest sample; found in 3 of 6

2025: not found

The highest sample, in 2022, was 0.4 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, it wasn’t found in its one sample.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Haloacetic acids (HAA5)
  • Lead

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 2 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), fluoride, nitrate, arsenic, chromium (total) and haloacetic acids (HAA5) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Stratton PWS’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from Jan. 14, 2020 to July 8, 2025.

Testing your own tap

Stratton PWS’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

The 3 labs Ohio certifies closest to the area Stratton PWS serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Cardinal Environmental Lab, LLC

    Youngstown, OH · about 41 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (330) 797-8844

  • Mahoning County Board of Health

    Youngstown, OH · about 41 miles

    Certified for bacteria

    (330) 270-2855

  • Canton Water Laboratory

    Canton, OH · about 43 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (330) 489-3035

All 76 certified labs for Ohio

Sources

PWSID OH4102512. Rebuilt from EPA data on Oct. 18, 2026.