Skip to content
TapBuff

Stow Public Water System

EPA’s and Ohio’s records have results for 33 contaminants in its water; 2 were found.

Serves 35,437 people · Surface water bought from another system · Stow, OH

Serves
35,437 people
Connections
13,297
Water source
Surface water bought from another system
Based in
Stow, OH
County
Summit
Owner
Private
The 2 ZIP codes it serves

44224, 44236

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 1 health-based violation since 2016, resolved in EPA’s file.

The violation⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Dec. 16, 2024 to Oct. 3, 2025.

Lead and copper: copper at 209 mg/L (2004) is left out of this report: it is one of the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Haloacetic acids (HAA5) and total trihalomethanes (TTHM): Ohio’s own results, samples taken from Jan. 8, 2020 to Oct. 8, 2025, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 46.6 ppb

Highest yearly average, 2020 to 2025 · Forms or is added in treatment

Averaged by year, the highest was 46.6 ppb, in 2025, below EPA’s legal limit of 60 ppb. Its highest single sample was 90.7 ppb. That was also the latest year on file. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 46.6 ppb, in 2014.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 49.3 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 47.1 ppb · Forms or is added in treatment

Averaged by year, the highest was 49.3 ppb, in 2024, below EPA’s legal limit of 80 ppb. Its highest single sample was 107 ppb. In 2025, the latest year on file, its 16 samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 65 ppb, in 2014.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Ohio utilities above EPA’s PFAS limits⁠
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

1 health-based violation since 2016 for the Lead and Copper Rule Revisions. It began Oct. 17, 2024.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024Resolved

Health-based violations only. 3 monitoring or reporting violations not shown.

Disinfectant

Stow Public Water System reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2024 to 2025 sampling for EPA. It also reported chlorine dioxide.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Stow Public Water System’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Dec. 16, 2024 to Oct. 3, 2025; Ohio’s results run from Jan. 8, 2020 to Oct. 8, 2025.

Testing your own tap

Stow Public Water System’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Stow Public Water System’s latest lead sampling in EPA’s records, 2022 to 2024, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Ohio certifies closest to the area Stow Public Water System serves, or a kit by mail

The 3 labs Ohio certifies closest to the area Stow Public Water System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • EnviroScience

    Stow, OH · about 2 miles

    (330) 688-0111

  • Alliance Technical Group, LLC-Akron

    Cuyahoga Falls, OH · about 5 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity

    (330) 253-8211

  • American Analytical Laboratories, Inc.

    Akron, OH · about 11 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (330) 535-1300

All 76 certified labs for Ohio⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Ohio certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Ohio’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID OH7704503. Rebuilt from EPA data on Oct. 25, 2026.