What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
100 people
Connections
65
Water source
Groundwater
Based in
Malvern, OH
County
Carroll
Owner
Private
The ZIP code it serves

44670

The short answer

Nothing in EPA’s and Ohio’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 1 health-based violation since 2016.

What was found

Lead and copper: lead at 5.0 mg/L (2005) and copper at 50 mg/L (2005) are left out of this report: they are among the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Total trihalomethanes (TTHM), fluoride, haloacetic acids (HAA5), arsenic, chromium (total) and nitrate: Ohio’s own results, samples taken from May 13, 2020 to Sept. 29, 2025, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits3

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

38.4ppb

Highest yearly average, 2020 to 2025

2025, one sample: 7.1 ppb

Averaged by year, the highest was 38.4 ppb, in 2021, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, its one sample was 7.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.5 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.57ppm

Highest yearly average, 2020 to 2023

2023, one sample: 0.52 ppm

Averaged by year, the highest was 0.57 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. In 2023, the latest year on file, its one sample was 0.52 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 0.55 ppm, in 2017.

What handles it

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

7.7ppb

Highest yearly average, 2020 to 2025

Averaged by year, the highest was 7.7 ppb, in 2025, below EPA’s legal limit of 60 ppb. That was also the latest year on file.

What handles it

No certification claim covers this compound yet.

4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Lead
  • Nitrate

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024—Unaddressed
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 4 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), fluoride, haloacetic acids (HAA5), arsenic, chromium (total) and nitrate results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Pride Valley MHP’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from May 13, 2020 to Sept. 29, 2025.

Testing your own tap

Pride Valley MHP’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

The 3 labs Ohio certifies closest to the area Pride Valley MHP serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Canton Water Laboratory

    Canton, OH · about 9 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (330) 489-3035

  • Canton City Health Department

    Canton, OH · about 10 miles

    Certified for bacteria

    (330) 489-3231

  • Ream & Haager Laboratories, Inc.

    Dover, OH · about 21 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (330) 343-3711

All 76 certified labs for Ohio

Sources

PWSID OH1000512. Rebuilt from EPA data on Oct. 18, 2026.