Skip to content
TapBuff

Northwestern W and SD - Oregon Wtln 200

EPA’s and Ohio’s records have results for 33 contaminants in its water; 3 were found.

Serves 9,629 people · Surface water bought from another system · Bowling Green, OH

Serves
9,629 people
Connections
2,867
Water source
Surface water bought from another system
Based in
Bowling Green, OH
County
Wood
Owner
Local government
The 4 ZIP codes it serves

43412, 43430, 43447, 43619

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from March 14 to Dec. 19, 2023.

Lead and copper: copper at 44 mg/L (2004) is left out of this report: it is one of the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): Ohio’s own results, samples taken from Jan. 9, 2020 to Oct. 8, 2025, with EPA’s 2012 to 2019 file for earlier years.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFHxA at 3.1 ppt: see it below.

Below EPA’s limits, 2 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 54.1 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 50.1 ppb · Forms or is added in treatment

Averaged by year, the highest was 54.1 ppb, in 2022, below EPA’s legal limit of 80 ppb. Its highest single sample was 80.9 ppb. In 2025, the latest year on file, its eight samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 84.6 ppb, in 2014, and EPA recorded violations in 2013, 2014 and 2015.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 16.8 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 12.6 ppb · Forms or is added in treatment

Averaged by year, the highest was 16.8 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 25 ppb. In 2025, the latest year on file, its eight samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 20.7 ppb, in 2014.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Ohio utilities above EPA’s PFAS limits⁠

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

PFAS found with no federal limit
CompoundHighest sampleFound inCertification claim
PFHxA3.1 ppt1 of 4None covers it
30 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Disinfectant

Northwestern W and SD - Oregon Wtln 200 reported adding chloramine before water enters its pipes, at its one sampling point, in its 2023 sampling for EPA. It also reported ozone.

What that means

Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Northwestern W and SD - Oregon Wtln 200’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 14 to Dec. 19, 2023; Ohio’s results run from Jan. 9, 2020 to Oct. 8, 2025.

Testing your own tap

Northwestern W and SD - Oregon Wtln 200’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Northwestern W and SD - Oregon Wtln 200’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Ohio certifies closest to the area Northwestern W and SD - Oregon Wtln 200 serves, or a kit by mail

The 3 labs Ohio certifies closest to the area Northwestern W and SD - Oregon Wtln 200 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Jones & Henry Laboratories

    Northwood, OH · about 4 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (419) 666-0411

  • BoJhun Environmental Services

    Fostoria, OH · about 28 miles

    Certified for bacteria

    (419) 436-7066

  • The Ohio State University Stone Laboratory

    Put-in-Bay, OH · about 29 miles

    (419) 285-1845

All 76 certified labs for Ohio⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Ohio certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Ohio’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID OH8704203. Rebuilt from EPA data on Oct. 25, 2026.