North Pine Estates
What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 50 people
- Connections
- 28
- Water source
- Groundwater
- Based in
- Lorain, OH
- County
- Williams
- Owner
- Private
The ZIP code it serves
The short answer
1 result is above the health goal. The worst: Lead, above the health goal. No health-based violations on file since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 2012 to 2025.
Fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5), arsenic, chromium (total) and nitrate: Ohio’s own results, samples taken from July 27, 2020 to Sept. 15, 2025, with EPA’s 2012 to 2019 file for earlier years.
Above the health goal1
Lead
Comes from pipes, often your own
5.0ppb
90th percentile, 2025
In the latest period, 9 in 10 homes sampled were at or below 5.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Below EPA’s limits3
Fluoride
Forms or is added in treatment
1.1ppm
Highest yearly average, 2022 to 2025
2025, one sample: 1.1 ppm
Averaged by year, the highest was 1.1 ppm, in 2022, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, its one sample was 1.1 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.1 ppm, in 2016.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Total trihalomethanes (TTHM)
Forms or is added in treatment
9.5ppb
Highest yearly average, 2020 to 2025
2025, one sample: 1.0 ppb
Averaged by year, the highest was 9.5 ppb, in 2023, below EPA’s legal limit of 80 ppb. In 2025, the latest year on file, its one sample was 1.0 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 21.3 ppb, in 2017.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5)
Forms or is added in treatment
1.3ppb
Highest yearly average, 2020 to 2025
2025: not found
Averaged by year, the highest was 1.3 ppb, in 2024, below EPA’s legal limit of 60 ppb. In 2025, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 7.3 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
- Nitrate
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claim: Lead Reduction
For: Lead
- NSF/ANSI 58
Claim: Lead Reduction
For: Lead
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Brita Everyday Pitcher with Elite Filter (OB46, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
Certified for: Lead
PUR PLUS 11-Cup Pitcher (PPT111W)
Pitcher
- NSF listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 4, 2026
Certified for: Lead
ZeroWater 10 Cup Pitcher (ZP-010)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53checked Oct. 4, 2026
Certified for: Lead
Culligan 10-Cup Pitcher with ZeroWater Technology (ZEROP10)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Fluoride, total trihalomethanes (TTHM), haloacetic acids (HAA5), arsenic, chromium (total) and nitrate results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. North Pine Estates’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from July 27, 2020 to Sept. 15, 2025.
Testing your own tap
The 3 labs Ohio certifies closest to the area North Pine Estates serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Kleinfelder Water Technologies Laboratory
McClure, OH · about 34 miles
Certified for bacteria
Eurofins DW and WW Central - Lima
Lima, OH · about 55 miles
Certified for bacteria
Jones & Henry Laboratories
Northwood, OH · about 57 miles
Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Ohio Environmental Protection Agency, Division of Drinking and Ground Waters, results from Jan. 2, 2020 to Dec. 31, 2025, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Ohio EPA, laboratories certified/accepted to perform analyses on public drinking water, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID OH8600812. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on LeadWhat each one does to health, where it comes from, and the certification claim that addresses it.About Lead
- Get the utility’s own reportNorth Pine Estates must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs