Skip to content
TapBuff

Morrow Village PWS

EPA’s and Ohio’s records have results for 7 contaminants in its water; 4 were found.

In the name, PWS means public water system.

Serves 3,360 people · Groundwater · Morrow, OH

Serves
3,360 people
Connections
1,313
Water source
Groundwater
Based in
Morrow, OH
County
Warren
Owner
Local government
The ZIP code it serves

45152

The short answer

None of the results here is above a limit in force today. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 1 health-based violation since 2016, with no fix on record in EPA’s file.

Filters for lead, if you want it lower⁠The violation⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

Lead and copper: EPA SDWIS monitoring periods ending 2018 to 2025. Copper at 94.5 mg/L (2004) is left out of this report: it is one of the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), fluoride, arsenic, chromium (total) and nitrate: Ohio’s own results, samples taken from April 13, 2020 to Dec. 18, 2025, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

Below EPA’s limits, 4 results

Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 23.6 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 1.6 ppb · Forms or is added in treatment

Averaged by year, the highest was 23.6 ppb, in 2021, below EPA’s legal limit of 60 ppb. Its highest single sample was 29.7 ppb. In 2025, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 4.8 ppb, in 2017.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 18.2 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 14.7 ppb · Forms or is added in treatment

Averaged by year, the highest was 18.2 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 27.9 ppb. In 2025, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 17.7 ppb, in 2017.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.9 ppb

90th percentile, 2025 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 1.9 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.13 ppm

Highest yearly average, 2022 to 2025 · Forms or is added in treatment

Averaged by year, the highest was 0.13 ppm, in 2025, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.47 ppm, in 2019.

What handles it

About fluoride
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Nitrate

Violations since 2016

1 health-based violation since 2016 for the Lead and Copper Rule Revisions. It began Oct. 17, 2024, and it has no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Lead and Copper Rule RevisionsThe required inventory of lead service lines was not completed or submitted on time.EPA: LSL InventoryOct. 17, 2024No fix on recordEPA: unaddressed

Health-based violations only. 5 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for lead, ranked⁠

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), fluoride, arsenic, chromium (total) and nitrate results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Morrow Village PWS’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from April 13, 2020 to Dec. 18, 2025.

Testing your own tap

Morrow Village PWS’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Morrow Village PWS’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 1.9 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Ohio certifies closest to the area Morrow Village PWS serves, or a kit by mail

The 3 labs Ohio certifies closest to the area Morrow Village PWS serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • ALS Environmental - Cincinnati

    Cincinnati, OH · about 15 miles

    Certified for lead and copper, metals, asbestos

    (513) 733-5336

  • Greene County Sanitary Engineering Laboratory

    Beavercreek, OH · about 26 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (937) 562-7450

  • Q Laboratories

    Cincinnati, OH · about 29 miles

    Certified for bacteria, nitrate

    (513) 471-1300

All 76 certified labs for Ohio⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Ohio certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Ohio’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID OH8300912. Rebuilt from EPA data on Oct. 25, 2026.