Skip to content
TapBuff

Matamoras Village

What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
896 people
Connections
500
Water source
Groundwater
Based in
New Matamoras, OH
County
Washington
Owner
Local government
The ZIP code it serves

45767

The short answer

Nothing in EPA’s and Ohio’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.

What was found

Total trihalomethanes (TTHM), nitrate, haloacetic acids (HAA5), fluoride, arsenic and chromium (total): Ohio’s own results, samples taken from June 2, 2020 to July 7, 2025, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits4

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

28.4ppb

Highest yearly average, 2020 to 2025

Averaged by year, the highest was 28.4 ppb, in 2025, below EPA’s legal limit of 80 ppb. Its highest single sample was 51.1 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 17.7 ppb, in 2014.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Nitrate

Comes from the source

Below EPA’s limits

2.4ppm

Highest sample; found in 6 of 6

2025, one sample: 1.6 ppm

The highest sample, in 2020, was 2.4 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its one sample was 1.6 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 3.0 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

4.3ppb

Highest yearly average, 2020 to 2025

2025: not found

Averaged by year, the highest was 4.3 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 4.8 ppb. In 2025, the latest year on file, it wasn’t found in any of its two samples.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.15ppm

Highest yearly average, 2022 to 2025

Averaged by year, the highest was 0.15 ppm, in 2025, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file.

What handles it

3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Lead

Violations since 2016

No health-based violations on file with EPA since 2016. There is 1 monitoring or reporting violation: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), nitrate, haloacetic acids (HAA5), fluoride, arsenic and chromium (total) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Matamoras Village’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from June 2, 2020 to July 7, 2025.

Testing your own tap

Matamoras Village’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

The 3 labs Ohio certifies closest to the area Matamoras Village serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Microbac Laboratories, Inc. - Marietta Division

    Marietta, OH · about 17 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, PFAS

    (740) 373-4071

  • SafeSource Water Analytics LLC

    McConnelsville, OH · about 37 miles

    Certified for bacteria, nitrate

    (740) 292-2002

  • Coshocton Environmental Testing, LLC

    Coshocton, OH · about 64 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

    (740) 622-3328

All 76 certified labs for Ohio

Sources

PWSID OH8400512. Rebuilt from EPA data on Oct. 18, 2026.