Skip to content
TapBuff

Commercial Point Village

EPA’s and Ohio’s records have results for 37 contaminants in its water; 8 were found.

Serves 3,497 people · Groundwater · Commercial Point, OH

Serves
3,497 people
Connections
2,000
Water source
Groundwater
Based in
Commercial Point, OH
County
Pickaway
Owner
Local government
The 2 ZIP codes it serves

43116, 43146

The short answer

None of the results here is above a limit in force today. Nitrate is above the health goal. No health-based violations on file since 2016.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What handles it⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from June 18, 2024 to Feb. 25, 2025.

Lead and copper: EPA SDWIS monitoring periods ending 2019 to 2025.

Nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, arsenic and chromium (total): Ohio’s own results, samples taken from Jan. 8, 2020 to Dec. 11, 2025, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFPeA at 3.1 ppt: see it below.

Above the health goal, 1 result

Nitrate

Comes from the source

Above the health goal

17.6 ppm

Highest sample; found in 9 of 11

2025 average: 0.88 ppm

One sample, in 2024, was above EPA’s legal limit of 10 ppm, at 17.6 ppm. The next sample at the same point, within 30 days, brought the average back under the limit. 10 ppm is also EPA’s health goal. In 2025, the latest year on file, its four samples averaged below the limit. EPA recorded no violation for nitrate at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.28 ppm, in 2017.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Below EPA’s limits, 6 results

Lead and arsenic have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
Lithium, Health reference level 10 ppbAt EPA’s benchmark, as EPA rounds; highest 14.8 ppb

Highest sample, Aug. 12, 2024; found in 2 of 2 · Comes from the source

The highest sample was 14.8 ppb. As EPA rounds results, that is at EPA’s health reference level of 10 ppb, not above it: EPA counts a result as above it from 15 ppb.

What handles it

No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.

How to read your utility’s report
About lithium
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 73.2 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 45.7 ppb · Forms or is added in treatment

Averaged by year, the highest was 73.2 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 90 ppb. In 2025, the latest year on file, its eight samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 72.7 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Lead, Action level 15 ppb · health goal zero; 90th percentile 3.0 ppb

90th percentile, 2025 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 3.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 11.1 ppb

Highest yearly average, 2020 to 2025 · Forms or is added in treatment

Averaged by year, the highest was 11.1 ppb, in 2025, below EPA’s legal limit of 60 ppb. Its highest single sample was 18 ppb. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 12.4 ppb, in 2014.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.4 ppm

Highest yearly average, 2022 to 2025 · Forms or is added in treatment

Averaged by year, the highest was 0.4 ppm, in 2025, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.47 ppm, in 2019.

What handles it

About fluoride
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.6 ppb

Highest yearly average, 2022 to 2025 · Comes from the source

Averaged by year, the highest was 0.6 ppb, in 2025, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. That was also the latest year on file.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
About arsenic
Ohio utilities above EPA’s PFAS limits⁠

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

PFAS found with no federal limit
CompoundHighest sampleFound inCertification claim
PFPeA3.1 ppt1 of 2None covers it
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Chromium (total)

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA
Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

  • NSF/ANSI 53

    Claims: Nitrate/Nitrite (30 ppm challenge), Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Nitrate, Lead, Arsenic

    Other claims that cover it: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Nitrate/Nitrite Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Nitrate, Lead, Arsenic

    Other claims that cover it: Nitrate; Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best reverse osmosis systems, ranked⁠

The best water filters for lead, ranked⁠

Disinfectant

Commercial Point Village reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2024 to 2025 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

Violations since 2016

No health-based violations on file with EPA since 2016. There are 3 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

What this report can’t tell you

  • Everything else. Nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, arsenic and chromium (total) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Commercial Point Village’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from June 18, 2024 to Feb. 25, 2025; Ohio’s results run from Jan. 8, 2020 to Dec. 11, 2025.

Testing your own tap

Commercial Point Village’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Commercial Point Village’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 3.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Commercial Point Village’s results flag: nitrate. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Ohio certifies closest to the area Commercial Point Village serves, or a kit by mail

The 3 labs Ohio certifies closest to the area Commercial Point Village serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Superior Laboratories

    Galloway, OH · about 13 miles

    Certified for bacteria

    (614) 870-6826

  • Benchmark Environmental Labs, Inc.

    Columbus, OH · about 20 miles

    Certified for bacteria

    (614) 267-4588

  • Ohio Department of Agriculture Consumer Protection Laboratory

    Reynoldsburg, OH · about 21 miles

    Certified for bacteria

    (614) 728-6230

All 76 certified labs for Ohio⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Ohio certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Ohio’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID OH6503512. Rebuilt from EPA data on Oct. 25, 2026.