Belmont Public Water System
What EPA’s and Ohio’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 400 people
- Connections
- 278
- Water source
- Groundwater
- Based in
- Belmont, OH
- County
- Belmont
- Owner
- Local government
The short answer
Nothing in EPA’s and Ohio’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.
What was found
Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, fluoride, arsenic and chromium (total): Ohio’s own results, samples taken from Jan. 22, 2020 to Sept. 9, 2025, with EPA’s 2012 to 2019 file for earlier years.
Below EPA’s limits4
Total trihalomethanes (TTHM)
Forms or is added in treatment
51.4ppb
Highest yearly average, 2020 to 2025
2025 average: 30.6 ppb
Averaged by year, the highest was 51.4 ppb, in 2021, below EPA’s legal limit of 80 ppb. Its highest single sample was 77.9 ppb. In 2025, the latest year on file, its two samples averaged 30.6 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 62.5 ppb, in 2012.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5)
Forms or is added in treatment
31.9ppb
Highest yearly average, 2020 to 2025
2025 average: 8.7 ppb
Averaged by year, the highest was 31.9 ppb, in 2024, below EPA’s legal limit of 60 ppb. Its highest single sample was 41.8 ppb. In 2025, the latest year on file, its two samples averaged 8.7 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 9.6 ppb, in 2018.
What handles it
No certification claim covers this compound yet.
Nitrate
Comes from the source
1.3ppm
Highest sample; found in 6 of 6
2025, one sample: 0.71 ppm
The highest sample, in 2020, was 1.3 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its one sample was 0.71 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 3.1 ppm, in 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Fluoride
Forms or is added in treatment
0.17ppm
Highest yearly average, 2020 to 2023
2023: not found
Averaged by year, the highest was 0.17 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. In 2023, the latest year on file, it wasn’t found in its one sample. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.1 ppm, in 2014.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
- Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 6 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, fluoride, arsenic and chromium (total) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Belmont Public Water System’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Ohio’s results run from Jan. 22, 2020 to Sept. 9, 2025.
Testing your own tap
The 3 labs Ohio certifies closest to the area Belmont Public Water System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Ream & Haager Laboratories, Inc.
Dover, OH · about 44 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts
Microbac Laboratories, Inc. - Marietta Division
Marietta, OH · about 50 miles
Certified for nitrate, lead and copper, metals, minerals and other inorganics, PFAS
Coshocton Environmental Testing, LLC
Coshocton, OH · about 51 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Ohio Environmental Protection Agency, Division of Drinking and Ground Waters, results from Jan. 2, 2020 to Dec. 31, 2025, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: Ohio EPA, laboratories certified/accepted to perform analyses on public drinking water, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID OH0700315. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Nothing here is above a health goalIn EPA’s and Ohio’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportBelmont Public Water System must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded