Aqua Ohio - Struthers
EPA’s and Ohio’s records have results for 37 contaminants in its water; 5 were found.
Serves 58,551 people · Surface water · Struthers, OH
- Serves
- 58,551 people
- Connections
- 24,530
- Water source
- Surface water
- Based in
- Struthers, OH
- County
- Mahoning
- Owner
- Private
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from Feb. 8 to Nov. 6, 2023.
Lead and copper: copper at 21.1 mg/L (2005) and copper at 69 mg/L (2004) are left out of this report: they are among the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.
Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic and chromium (total): Ohio’s own results, samples taken from Jan. 6, 2020 to Dec. 1, 2025, with EPA’s 2012 to 2019 file for earlier years.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFBA at 8.9 ppt: see it below.
Below EPA’s limits, 4 results
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 40.6 ppb
Highest yearly average, 2020 to 2025 · 2025 average: 35.5 ppb · Forms or is added in treatment
Averaged by year, the highest was 40.6 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 54.4 ppb. In 2025, the latest year on file, its 32 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 49.2 ppb, in 2012.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 25.2 ppb
Highest yearly average, 2020 to 2025 · 2025 average: 23.7 ppb · Forms or is added in treatment
Averaged by year, the highest was 25.2 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 48.7 ppb. In 2025, the latest year on file, its 32 samples averaged below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 27.5 ppb, in 2012.
What handles it
No certification claim covers this compound yet.
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.91 ppm
Highest yearly average, 2020 to 2025 · 2025, one sample: 0.8 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.91 ppm, in 2020, below EPA’s legal limit of 4.0 ppm. In 2025, the latest year on file, its one sample was below the limit.
Earlier, 2012 to 2019
From 2012 to 2019, EPA’s file shows a highest yearly average of 1.1 ppm, in 2013.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Nitrate, Legal limit 10 ppm; highest 0.43 ppm
Highest sample; found in 17 of 71 · 2025 average: 0.083 ppm · Comes from the source
The highest sample, in 2025, was 0.43 ppm, below EPA’s legal limit of 10 ppm. That was also the latest year on file, and its 12 samples averaged below the limit.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFBA | 8.9 ppt | 1 of 4 | None covers it |
32 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Arsenic
- Chromium (total)
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. There are 7 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Disinfectant
Aqua Ohio - Struthers reported adding chloramine before water enters its pipes, at its one sampling point, in its 2023 sampling for EPA.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, nitrate, arsenic and chromium (total) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Aqua Ohio - Struthers’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Feb. 8 to Nov. 6, 2023; Ohio’s results run from Jan. 6, 2020 to Dec. 1, 2025.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Aqua Ohio - Struthers’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Ohio certifies closest to the area Aqua Ohio - Struthers serves, or a kit by mail
The 3 labs Ohio certifies closest to the area Aqua Ohio - Struthers serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Cardinal Environmental Lab, LLC
Youngstown, OH · about 9 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts
Mahoning County Board of Health
Youngstown, OH · about 11 miles
Certified for bacteria
Portage County Water Resources
Ravenna, OH · about 34 miles
Certified for bacteria, nitrate, minerals and other inorganics
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Ohio certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Ohio’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded
- Get the utility’s own reportAqua Ohio - Struthers must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Ohio Environmental Protection Agency, Division of Drinking and Ground Waters, results from Jan. 2, 2020 to Dec. 31, 2025, read Oct. 17, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: Ohio EPA, laboratories certified/accepted to perform analyses on public drinking water, read Oct. 10, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID OH5001611. Rebuilt from EPA data on Oct. 25, 2026.