Skip to content
TapBuff

Ada Village

EPA’s and Ohio’s records have results for 37 contaminants in its water; 5 were found.

Serves 5,334 people · Groundwater · Ada, OH

Serves
5,334 people
Connections
1,848
Water source
Groundwater
Based in
Ada, OH
County
Hardin
Owner
Local government
The ZIP code it serves

45810

The short answer

None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. No health-based violations on file since 2016.

This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from April 11 to Oct. 18, 2023.

Lead and copper: copper at 50 mg/L (2004) is left out of this report: it is one of the results Ohio sent EPA in 2006, all at µg/L magnitudes though EPA’s file marks them mg/L.

Total trihalomethanes (TTHM), fluoride, haloacetic acids (HAA5), nitrate, arsenic and chromium (total): Ohio’s own results, samples taken from May 4, 2020 to Sept. 8, 2025, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.
Health reference level:
A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Above EPA’s health benchmark, 1 result

Lithium

Comes from the source

Above EPA’s health benchmark

45.8 ppb

Highest sample, Oct. 18, 2023; found in 2 of 2

The highest sample was 45.8 ppb, about 4.6 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.

What handles it

No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.

How to read your utility’s report

Below EPA’s limits, 4 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 46.9 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 38.5 ppb · Forms or is added in treatment

Averaged by year, the highest was 46.9 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 50.6 ppb. In 2025, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 45.8 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Fluoride, Legal limit 4.0 ppm; highest yearly average 1.1 ppm

Highest yearly average, 2021 to 2024 · 2024, one sample: 0.98 ppm · Forms or is added in treatment

Averaged by year, the highest was 1.1 ppm, in 2021, below EPA’s legal limit of 4.0 ppm. In 2024, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 1.0 ppm, in 2013.

What handles it

About fluoride
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 8.6 ppb

Highest yearly average, 2020 to 2025 · 2025 average: 5.2 ppb · Forms or is added in treatment

Averaged by year, the highest was 8.6 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 11.1 ppb. In 2025, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 14.3 ppb, in 2019.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Nitrate, Legal limit 10 ppm; highest 0.46 ppm

Highest sample; found in 5 of 6 · 2025, one sample: 0.3 ppm · Comes from the source

The highest sample, in 2023, was 0.46 ppm, below EPA’s legal limit of 10 ppm. In 2025, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.25 ppm, in 2012.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Ohio utilities above EPA’s PFAS limits⁠
32 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Lead

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016. There are 3 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Disinfectant

Ada Village reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), fluoride, haloacetic acids (HAA5), nitrate, arsenic and chromium (total) results here are Ohio’s own from 2020 on, with EPA’s national file for 2012 to 2019. Ada Village’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from April 11 to Oct. 18, 2023; Ohio’s results run from May 4, 2020 to Sept. 8, 2025.

Testing your own tap

Ada Village’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Ohio certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Ada Village’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
  • What Ada Village’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Ohio certifies closest to the area Ada Village serves, or a kit by mail

The 3 labs Ohio certifies closest to the area Ada Village serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins DW and WW Central - Lima

    Lima, OH · about 19 miles

    Certified for bacteria

    (419) 223-1362

  • Logan County Health District Laboratory

    Bellefontaine, OH · about 29 miles

    Certified for bacteria

    (937) 592-9040

  • BoJhun Environmental Services

    Fostoria, OH · about 34 miles

    Certified for bacteria

    (419) 436-7066

All 76 certified labs for Ohio⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Ohio certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Ohio’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID OH3300012. Rebuilt from EPA data on Oct. 25, 2026.