South Central Regional Water District
EPA’s records have results for 33 contaminants in its water; 4 were found.
Serves 3,700 people · Groundwater bought from another system · Bismarck, ND
- Serves
- 3,700 people
- Connections
- 1,720
- Water source
- Groundwater bought from another system
- Based in
- Bismarck, ND
- County
- Burleigh
- Owner
- Private
The short answer
None of the results here is above a limit in force today. Lithium is above EPA’s health benchmark. No health-based violations on file since 2016.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from March 7 to Dec. 12, 2023.
Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 2.0 ppm, for the period ending March 28, 1994. None since is on file, so it is not counted as a current finding.
Total trihalomethanes (TTHM) and haloacetic acids (HAA5): EPA’s compliance monitoring file, samples taken from Aug. 21, 2012 to Oct. 14, 2019. Newer results are in the utility’s annual water quality report.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest PFBA at 5.9 ppt: see it below.
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
79.4 ppb
Highest sample, Dec. 12, 2023; found in 4 of 4
The highest sample was 79.4 ppb, about 7.9 times EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 2 results
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 53.1 ppb
Highest yearly average, 2012 to 2019 · 2019 average: 32.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 53.1 ppb, in 2012, below EPA’s legal limit of 80 ppb. Its highest single sample was 92.2 ppb. In 2019, the latest year on file, its eight samples averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility from 2012 to 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 25.8 ppb
Highest yearly average, 2012 to 2019 · 2019 average: 15.7 ppb · Forms or is added in treatment
Averaged by year, the highest was 25.8 ppb, in 2017, below EPA’s legal limit of 60 ppb. Its highest single sample was 67.8 ppb. In 2019, the latest year on file, its eight samples averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility from 2012 to 2019.
What handles it
No certification claim covers this compound yet.
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| PFBA | 5.9 ppt | 1 of 4 | None covers it |
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Disinfectant
South Central Regional Water District reported adding chloramine before water enters its pipes, at its one sampling point, in its 2023 sampling for EPA.
What that means
Chloramine is chlorine combined with ammonia. It lasts longer in the pipes, and unlike chlorine, it doesn’t leave water that sits out. A filter’s chlorine claim doesn’t cover it: look for the separate chloramine claim under NSF/ANSI 42. No shower filter can carry one: NSF/ANSI 177, the shower filter standard, covers free chlorine only. Fish, turtles and frogs need it removed from their water. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Newer results, and everything else. Nitrate, arsenic, fluoride, chromium, uranium and disinfection byproduct results here come from EPA’s national compliance file, which ends in 2019. South Central Regional Water District’s own annual report, which it must send you every year, has newer results and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 7 to Dec. 12, 2023; EPA’s compliance samples are from Aug. 21, 2012 to Oct. 14, 2019.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. South Central Regional Water District’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What South Central Regional Water District’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
Labs North Dakota certifies, or a kit by mail
TapBuff hasn’t read North Dakota’s list of certified labs yet. The national page links every state’s own list.
Certified labs, state by stateOr test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that North Dakota certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against North Dakota’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on lithiumWhat it does to health, where it comes from, and the certification claim that addresses it.About lithium
- Get the utility’s own reportSouth Central Regional Water District must send you a water quality report every year. It has newer results than EPA’s national file, which ends in 2019.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID ND0801154. Rebuilt from EPA data on Oct. 25, 2026.