What EPA’s and New York’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
49 people
Connections
23
Water source
Groundwater
Based in
Eaton (T), NY
County
Madison
Owner
Private
The ZIP code it serves

13310

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Arsenic, above the legal limit. 9 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2002 to 2020.

Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: New York’s yearly summaries per water system, 2020 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from Nov. 13, 2012 to April 2, 2018. Newer results are in the utility’s annual water quality report.

Above the legal limit1

Arsenic

Comes from the source

Above the legal limit

7.1ppb

Highest yearly average, 2020 to 2024

2024 average: 6.1 ppb

Averaged by year, the highest was 7.1 ppb, in 2022: below EPA’s legal limit of 10 ppb, but above its health goal of zero. Its highest single sample was 21.5 ppb. In 2024, the latest year on file, it averaged 6.1 ppb. EPA judges this limit at each sampling point, and recorded a violation for arsenic at this utility in 2025. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 12.8 ppb, in 2017, and EPA recorded violations in 2016, 2017 and 2018.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

1.6ppb

90th percentile, 2018 to 2020

In the latest period, 9 in 10 homes sampled were at or below 1.6 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits2

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.2ppm

Highest yearly average, 2012 to 2018

2018, one sample: 0.2 ppm

Averaged by year, the highest was 0.2 ppm, in 2012, below EPA’s legal limit of 4.0 ppm. In 2018, the latest year on file, its one sample was 0.2 ppm.

What handles it

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

0.77ppb

Highest yearly average, 2020 to 2023

Averaged by year, the highest was 0.77 ppb, in 2023, below EPA’s legal limit of 80 ppb. That was also the latest year on file.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Haloacetic acids (HAA5)
  • Nitrate

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Arsenic (Pentavalent)<=50 ppb Reduction, Lead Reduction

    For: Arsenic, Lead

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
ArsenicA sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single SampleJan. 1, 2025 to March 31, 20250.01 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2018 to March 31, 201810.9 UG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2017 to Dec. 31, 201711.7 UG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2017 to Sept. 30, 201711.5 UG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2017 to June 30, 201711.8 UG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2017 to March 31, 201712.6 UG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2016 to Dec. 31, 201610.6 UG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2016 to Sept. 30, 201611.2 UG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 201610.9 UG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record.

What this report can’t tell you

  • Everything else. Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are New York’s own yearly summaries from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. White Pines Mobile Home Park’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; New York’s yearly summaries cover 2020 to 2024; EPA’s compliance samples are from Nov. 13, 2012 to April 2, 2018.

Testing your own tap

White Pines Mobile Home Park’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

The 3 labs New York certifies closest to the area White Pines Mobile Home Park serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • A & P Water Testing

    Morrisville, NY · about 6 miles

    Certified for bacteria

    (315) 684-3169

  • Mohawk Valley Water Authority

    Utica, NY · about 27 miles

    Certified for bacteria, nitrate, lead and copper, minerals and other inorganics

    (315) 792-0338

  • Certified Environmental Services Inc.

    North Syracuse, NY · about 33 miles

    Certified for bacteria, nitrate, minerals and other inorganics

    (315) 478-2374

All 161 certified labs for New York

Sources

PWSID NY2600976. Rebuilt from EPA data on Oct. 18, 2026.