What EPA’s and New York’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
400 people
Connections
100
Water source
Surface water
Based in
Aurora (V), NY
County
Cayuga
Owner
Local government
The ZIP code it serves

13026

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Total trihalomethanes (TTHM), above the legal limit. 5 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2005 to 2025.

Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate and arsenic: New York’s yearly summaries per water system, 2020 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from Oct. 29, 2012 to Nov. 20, 2019. Newer results are in the utility’s annual water quality report.

Above the legal limit1

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the legal limit

84.7ppb

Highest yearly average, 2020 to 2024

2024 average: 38.8 ppb

Averaged by year, the highest was 84.7 ppb, in 2021, above EPA’s legal limit of 80 ppb. Its highest single sample was 139 ppb. In 2024, the latest year on file, it averaged 38.8 ppb. EPA recorded violations for total trihalomethanes (TTHM) at this utility in 2021 and 2022. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 86.2 ppb, in 2015, and EPA recorded violations in 2015 and 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Above the health goal1

Lead

Comes from pipes, often your own

Above the health goal

5.0ppb

90th percentile, 2023 to 2025

In the latest period, 9 in 10 homes sampled were at or below 5.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

Below EPA’s limits3

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

19ppb

Highest yearly average, 2020 to 2024

2024 average: 9.1 ppb

Averaged by year, the highest was 19 ppb, in 2023, below EPA’s legal limit of 60 ppb. Its highest single sample was 37 ppb. In 2024, the latest year on file, it averaged 9.1 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 11.5 ppb, in 2015.

What handles it

No certification claim covers this compound yet.

Nitrate

Comes from the source

Below EPA’s limits

1.2ppm

Highest sample; found in 5 of 5

2024 average: 0.87 ppm

The highest sample, in 2021, was 1.2 ppm, below EPA’s legal limit of 10 ppm. In 2024, the latest year on file, it averaged 0.87 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 1.6 ppm, in 2014.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.13ppm

Highest yearly average, 2012 to 2019

2019: not found

Averaged by year, the highest was 0.13 ppm, in 2016, below EPA’s legal limit of 4.0 ppm. In 2019, the latest year on file, it wasn’t found in its one sample.

What handles it

2 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claims: Trihalomethanes (TTHM) Reduction, Lead Reduction

    For: Total trihalomethanes (TTHM), Lead

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2022 to March 31, 202292 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2021 to Dec. 31, 202192 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2016 to Sept. 30, 201685.5 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2016 to June 30, 201686.2 UG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2016 to March 31, 201695.4 UG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate and arsenic results here are New York’s own yearly summaries from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Village of Aurora’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; New York’s yearly summaries cover 2020 to 2024; EPA’s compliance samples are from Oct. 29, 2012 to Nov. 20, 2019.

Testing your own tap

Village of Aurora’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

The 3 labs New York certifies closest to the area Village of Aurora serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Panek Laboratory LLC Dba Jli Environmental Laboratories

    Auburn, NY · about 13 miles

    Certified for bacteria, nitrate

    (315) 253-4433

  • R&J Laboratories

    Penn Yan, NY · about 22 miles

    Certified for lead and copper

    (315) 536-9302

  • Community Science Institute, Inc.

    Ithaca, NY · about 23 miles

    Certified for bacteria, nitrate

    (607) 257-6606

All 161 certified labs for New York

Sources

PWSID NY0512920. Rebuilt from EPA data on Oct. 18, 2026.