Skip to content
TapBuff

Rhinebeck Village Water

EPA’s and New York’s records have results for 38 contaminants in its water; 4 were found.

Serves 6,000 people · Surface water · Rhinebeck (V), NY

Serves
6,000 people
Connections
1,835
Water source
Surface water
Based in
Rhinebeck (V), NY
County
Dutchess
Owner
Local government
The 2 ZIP codes it serves

12572, 12574

The short answer

None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. 1 health-based violation since 2016, resolved in EPA’s file.

Filters for lead, if you want it lower⁠The violation⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

PFAS and lithium: EPA UCMR 5, samples taken from Jan. 13 to Oct. 14, 2025.

Lead and copper: EPA SDWIS monitoring periods ending 2003 to 2023.

Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate and arsenic: New York’s yearly summaries per water system, 2020 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Chromium (total), fluoride and uranium: EPA’s compliance monitoring file, samples taken from Feb. 14, 2012 to Feb. 12, 2019. Newer results are in the utility’s annual water quality report.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.

Below EPA’s limits, 4 results

Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Action level:
Triggers action. If more than 10% of homes sampled are above it, the utility must act.
90th percentile:
How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 47.4 ppb

Highest yearly average, 2020 to 2024 · 2024 average: 33.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 47.4 ppb, in 2023, below EPA’s legal limit of 60 ppb. Its highest single sample was 83.3 ppb. In 2024, the latest year on file, it averaged below the limit. EPA recorded no violation for haloacetic acids (HAA5) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 44.5 ppb, in 2017, and EPA recorded a violation in 2019.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 59 ppb

Highest yearly average, 2020 to 2024 · 2024 average: 36.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 59 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 104 ppb. In 2024, the latest year on file, it averaged below the limit. EPA recorded no violation for total trihalomethanes (TTHM) at this utility since 2020.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 60 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Lead, Action level 15 ppb · health goal zero; 90th percentile 2.1 ppb

90th percentile, 2021 to 2023 · Comes from pipes, often your own

In the latest period, 9 in 10 homes sampled were at or below 2.1 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.

What handles it

About lead
Nitrate, Legal limit 10 ppm; highest 0.57 ppm

Highest sample; found in 6 of 6 · 2023 average: 0.35 ppm · Comes from the source

The highest sample, in 2022, was 0.57 ppm, below EPA’s legal limit of 10 ppm. In 2023, the latest year on file, it averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 0.8 ppm, in 2013.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
New York utilities above EPA’s PFAS limits⁠
34 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.

From routine monitoring

  • Arsenic
  • Chromium (total)
  • Fluoride
  • Uranium

PFAS and lithium, from EPA’s UCMR 5 sampling

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lithium
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

1 health-based violation since 2016 for total Haloacetic Acids (HAA5). It began April 1, 2019.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Total Haloacetic Acids (HAA5)The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2019 to June 30, 2019, 61,000 ppbResolved

Health-based violations only. 2 monitoring or reporting violations not shown.

Skip past the filters

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

2 more filters
Compare five-year costs

Every filter certified for it⁠

The best water filters for lead, ranked⁠

Disinfectant

Rhinebeck Village Water reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2025 sampling for EPA.

What that means

Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.

What this report can’t tell you

  • Everything else. Haloacetic acids (HAA5), total trihalomethanes (TTHM), nitrate and arsenic results here are New York’s own yearly summaries from 2020 on, with EPA’s national file for 2012 to 2019. Chromium (total), fluoride and uranium come from EPA’s file alone, which ends in 2019. Rhinebeck Village Water’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from Jan. 13 to Oct. 14, 2025; New York’s yearly summaries cover 2020 to 2024; EPA’s compliance samples are from Feb. 14, 2012 to Feb. 12, 2019.

Testing your own tap

Rhinebeck Village Water’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Rhinebeck Village Water’s latest lead sampling in EPA’s records, 2021 to 2023, had a 90th percentile of 2.1 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs New York certifies closest to the area Rhinebeck Village Water serves, or a kit by mail

The 3 labs New York certifies closest to the area Rhinebeck Village Water serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Aqua Check Laboratories, Inc.

    Stone Ridge, NY · about 15 miles

    Certified for bacteria

    (845) 687-0420

  • Poughkeepsies' Water Treatment Facility

    Poughkeepsie, NY · about 15 miles

    Certified for bacteria

    (845) 451-4173

  • Environmental Labworks Inc.

    Marlboro, NY · about 22 miles

    Certified for bacteria

    (845) 236-7823

All 161 certified labs for New York⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that New York certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against New York’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID NY1302776. Rebuilt from EPA data on Oct. 25, 2026.