What EPA’s and New York’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
447 people
Connections
149
Water source
Groundwater
Based in
Dryden (T), NY
County
Tompkins
Owner
Private
The ZIP code it serves

14850

The short answer

1 result is above the health goal. The worst: Arsenic, above the health goal. No health-based violations on file since 2016.

What handles it

What was found

Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate: New York’s yearly summaries per water system, 2020 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Fluoride and chromium (total): EPA’s compliance monitoring file, samples taken from March 3, 2014 to Oct. 10, 2017. Newer results are in the utility’s annual water quality report.

Above the health goal1

Arsenic

Comes from the source

Above the health goal

7.0ppb

Highest yearly average, 2021 to 2023

Averaged by year, the highest was 7.0 ppb, in 2023: below EPA’s legal limit of 10 ppb, but above its health goal of zero. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 5.0 ppb, in 2017.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Below EPA’s limits3

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

12ppb

Highest yearly average, 2022

Averaged by year, the highest was 12 ppb, in 2022, below EPA’s legal limit of 80 ppb. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 8.7 ppb, in 2013.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

3.6ppb

Highest yearly average, 2022

Averaged by year, the highest was 3.6 ppb, in 2022, below EPA’s legal limit of 60 ppb. That is the only year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.9 ppb, in 2016.

What handles it

No certification claim covers this compound yet.

Fluoride

Forms or is added in treatment

Below EPA’s limits

0.2ppm

Highest yearly average, 2014 to 2017

Averaged by year, the highest was 0.2 ppm, in 2017, below EPA’s legal limit of 4.0 ppm. That was also the latest year on file.

What handles it

3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Lead
  • Nitrate

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claim: Arsenic (Pentavalent)<=50 ppb Reduction

    For: Arsenic

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best reverse osmosis systems, ranked

Violations since 2016

No health-based violations on file with EPA since 2016. There are 3 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Arsenic, total trihalomethanes (TTHM), haloacetic acids (HAA5) and nitrate results here are New York’s own yearly summaries from 2020 on, with EPA’s national file for 2012 to 2019. Fluoride and chromium (total) come from EPA’s file alone, which ends in 2019. Hanshaw Village MHP’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; New York’s yearly summaries cover 2020 to 2024; EPA’s compliance samples are from March 3, 2014 to Oct. 10, 2017.

Testing your own tap

Hanshaw Village MHP’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

The 3 labs New York certifies closest to the area Hanshaw Village MHP serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Community Science Institute, Inc.

    Ithaca, NY · under a mile

    Certified for bacteria, nitrate

    (607) 257-6606

  • Microbac New York-Cortland

    Cortland, NY · about 18 miles

    Certified for bacteria

    (607) 753-3403

  • R&J Laboratories

    Penn Yan, NY · about 33 miles

    Certified for lead and copper

    (315) 536-9302

All 161 certified labs for New York

Sources