Skip to content
TapBuff

Colden Water District #1

What EPA’s and New York’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
445 people
Connections
178
Water source
Surface water bought from another system
Based in
Colden (T), NY
County
Erie
Owner
Local government
The ZIP code it serves

14033

The short answer

1 result is above the limit’s level with no violation recorded. The worst: Total trihalomethanes (TTHM), above the limit’s level, no violation. No health-based violations on file since 2016.

What handles it

What was found

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): New York’s yearly summaries per water system, 2020 to 2024, with EPA’s 2012 to 2019 file for earlier years.

Above the limit’s level, no violation recorded1

Total trihalomethanes (TTHM)

Forms or is added in treatment

Above the limit’s level, no violation

82.1ppb

Highest yearly average, 2020 to 2024

2024 average: 57 ppb

Averaged by year, the highest was 82.1 ppb, in 2020, above EPA’s legal limit of 80 ppb. Its highest single sample was 99.5 ppb. In 2024, the latest year on file, it averaged 57 ppb. EPA judges this limit on running averages at each sampling point, and recorded no violation for total trihalomethanes (TTHM) at this utility since 2020. Results like these with no violation often include water sampled before treatment or blending; the utility’s annual report says what reaches the tap. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 83.9 ppb, in 2016.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Below EPA’s limits1

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

48.3ppb

Highest yearly average, 2020 to 2024

2024 average: 31.8 ppb

Averaged by year, the highest was 48.3 ppb, in 2023, below EPA’s legal limit of 60 ppb. Its highest single sample was 53.4 ppb. In 2024, the latest year on file, it averaged 31.8 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 35.7 ppb, in 2015.

What handles it

No certification claim covers this compound yet.

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

    Other certifiers’ wording: VOC Reduction

  • NSF/ANSI 58

    Claim: Trihalomethanes (TTHM) Reduction

    For: Total trihalomethanes (TTHM)

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

Violations since 2016

No health-based violations on file with EPA since 2016. There are 7 monitoring or reporting violations: a sample missed, late or not reported.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are New York’s own yearly summaries from 2020 on, with EPA’s national file for 2012 to 2019. Colden Water District #1’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; New York’s yearly summaries cover 2020 to 2024.

Testing your own tap

Colden Water District #1’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New York certifies.

The 3 labs New York certifies closest to the area Colden Water District #1 serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Mcandrew Laboratory Inc.

    Orchard Park, NY · about 7 miles

    Certified for bacteria

    (716) 649-7960

  • EMSL Analytical Inc.

    Depew, NY · about 17 miles

    Certified for bacteria, asbestos

    (716) 651-0030

  • Biotrax Testing Laboratory

    Cheektowaga, NY · about 20 miles

    Certified for bacteria

    (716) 651-0146

All 161 certified labs for New York

Sources

PWSID NY1450020. Rebuilt from EPA data on Oct. 18, 2026.