Skip to content
TapBuff

Lake Como Water Dept

What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
3,000 people
Connections
1,084
Water source
Surface water bought from another system
Based in
South Belmar Boro, NJ
County
Monmouth
Owner
Local government
The ZIP code it serves

07719

The short answer

Nothing in EPA’s and CDC’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 4 health-based violations since 2016.

What was found

Total trihalomethanes (TTHM) and haloacetic acids (HAA5): New Jersey’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.

Below EPA’s limits2

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

71.5ppb

Highest yearly average, 2020 to 2023

2023 average: 39.5 ppb

Averaged by year, the highest was 71.5 ppb, in 2021, below EPA’s legal limit of 80 ppb. In 2023, the latest year on file, it averaged 39.5 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 82.7 ppb, in 2018, and EPA recorded violations in 2018 and 2019.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

13.5ppb

Highest yearly average, 2020 to 2023

2023 average: 13.4 ppb

Averaged by year, the highest was 13.5 ppb, in 2022, below EPA’s legal limit of 60 ppb. In 2023, the latest year on file, it averaged 13.4 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 21.2 ppb, in 2015.

What handles it

No certification claim covers this compound yet.

One compound tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Lead

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2019 to Sept. 30, 20190.081 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2019 to June 30, 20190.083 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2019 to March 31, 20190.084 MG/LResolved
TTHMThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2018 to Dec. 31, 20180.085 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 9 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are New Jersey’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Lake Como Water Dept’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for New Jersey cover 2020 to 2023.

Testing your own tap

Lake Como Water Dept’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New Jersey certifies.

The 3 labs New Jersey certifies closest to the area Lake Como Water Dept serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Lyons Environmental Services LLC

    Neptune, NJ · about 3 miles

    (732) 566-0038

  • E Runyon T/A Aquatic Services

    Howell, NJ · about 7 miles

    (732) 938-6366

  • ALS Environmental - Toms River

    Toms River, NJ · about 14 miles

    (203) 325-1371

All 89 certified labs for New Jersey

Sources

PWSID NJ1347001. Rebuilt from EPA data on Oct. 18, 2026.