Skip to content
TapBuff

Delaware Township Mua

What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
500 people
Connections
173
Water source
Groundwater
Based in
Delaware Twp., NJ
County
Hunterdon
Owner
Local government
The ZIP code it serves

08559

The short answer

Nothing in EPA’s and CDC’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 2 health-based violations since 2016.

What was found

Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 2.5 ppm, for the period ending Dec. 31, 1993. None since is on file, so it is not counted as a current finding.

Nitrate, haloacetic acids (HAA5), total trihalomethanes (TTHM) and arsenic: New Jersey’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.

Chromium (total), fluoride and uranium: EPA’s compliance monitoring file, samples taken from April 2, 2012 to March 20, 2018. Newer results are in the utility’s annual water quality report.

Below EPA’s limits3

Nitrate

Comes from the source

Below EPA’s limits

4.4ppm

Highest yearly average, 2020 to 2023

Averaged by year, the highest was 4.4 ppm, in 2023, below EPA’s legal limit of 10 ppm. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 4.3 ppm, in 2017.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”

Haloacetic acids (HAA5)

Forms or is added in treatment

Below EPA’s limits

1.8ppb

Highest yearly average, 2020 to 2023

2023: not found

Averaged by year, the highest was 1.8 ppb, in 2021, below EPA’s legal limit of 60 ppb. In 2023, the latest year on file, it wasn’t found. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 6.0 ppb, in 2013.

What handles it

No certification claim covers this compound yet.

Total trihalomethanes (TTHM)

Forms or is added in treatment

Below EPA’s limits

2.0ppb

Highest yearly average, 2020 to 2023

2023 average: 1.9 ppb

Averaged by year, the highest was 2.0 ppb, in 2020, below EPA’s legal limit of 80 ppb. In 2023, the latest year on file, it averaged 1.9 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 3.4 ppb, in 2018.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
5 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Fluoride
  • Lead
  • Uranium

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper RuleWater chemistry used to keep pipes from corroding was outside the required range.EPA: WQP Entry Point/Tap Treatment Technique Non-ComplianceJuly 1, 2020 to Dec. 31, 2020—Resolved
Lead and Copper RuleWater chemistry used to keep pipes from corroding was outside the required range.EPA: WQP Entry Point/Tap Treatment Technique Non-ComplianceJan. 1, 2020 to June 30, 2020—Resolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 13 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Nitrate, haloacetic acids (HAA5), total trihalomethanes (TTHM) and arsenic results here are New Jersey’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Chromium (total), fluoride and uranium come from EPA’s file alone, which ends in 2019. Delaware Township Mua’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for New Jersey cover 2020 to 2023; EPA’s compliance samples are from April 2, 2012 to March 20, 2018.

Testing your own tap

Delaware Township Mua’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New Jersey certifies.

The 3 labs New Jersey certifies closest to the area Delaware Township Mua serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Pace Analytical Services, LLC - Ewing

    Ewing, NJ · about 14 miles

    (609) 737-3477

  • New Jersey Department of Health

    West Trenton, NJ · about 14 miles

    (609) 718-8169

  • Sadat Associates Inc.

    Ewing, NJ · about 17 miles

    (609) 826-9600

All 89 certified labs for New Jersey

Sources

PWSID NJ1007001. Rebuilt from EPA data on Oct. 18, 2026.