Northpointe Water
What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 48 people
- Connections
- 19
- Water source
- Groundwater
- Based in
- Thornton, NH
- County
- Grafton
- Owner
- Private
The ZIP code it serves
The short answer
2 results are above EPA’s legal limit. The worst: Lead, above the action level. 9 health-based violations since 2016.
What handles itWhat was found
Lead and copper: EPA SDWIS monitoring periods ending 1993 to 2008.
Copper: EPA’s file records a utility’s copper only when it exceeds the action level. The last here was 3.9 ppm, for the period ending Dec. 31, 2003. None since is on file, so it is not counted as a current finding.
Nitrate, arsenic and total trihalomethanes (TTHM): New Hampshire’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.
Chromium (total), fluoride and uranium: EPA’s compliance monitoring file, samples taken from Oct. 21, 2015 to Oct. 15, 2018. Newer results are in the utility’s annual water quality report.
Above the legal limit2
Lead
Comes from pipes, often your own
20ppb
90th percentile, 2008
In the latest period, 9 in 10 homes sampled were at or below 20 ppb, above EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Nitrate
Comes from the source
8.9ppm
Highest yearly average, 2020 to 2023
Averaged by year, the highest was 8.9 ppm, in 2023, below EPA’s legal limit of 10 ppm. That was also the latest year on file. EPA judges this limit at each sampling point, and recorded violations for nitrate at this utility in 2023, 2024 and 2025. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 12.6 ppm, in 2018, and EPA recorded violations in 2017, 2018 and 2019.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Below EPA’s limits1
Chromium (total)
Comes from the source
2.0ppb
Highest yearly average, 2015 to 2018
Averaged by year, the highest was 2.0 ppb, in 2018, below EPA’s legal limit of 100 ppb. That was also the latest year on file.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Fluoride
- Total trihalomethanes (TTHM)
- Uranium
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”
- NSF/ANSI 53
Claims: Lead Reduction, Nitrate/Nitrite (30 ppm challenge)
For: Lead, Nitrate
- NSF/ANSI 58
Claims: Lead Reduction, Nitrate/Nitrite Reduction
For: Lead, Nitrate
Other certifiers’ wording: Nitrate
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Culligan 10-Cup Pitcher with ZeroWater Technology (ZEROP10)
Pitcher
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead, Nitrate
Aquasana SmartFlow Reverse Osmosis (AQ-SFRO2)
Under-sink reverse osmosis
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 9, 2026
Certified for: Lead, Nitrate
Countertop reverse osmosis
- IAPMO listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 58NSF/ANSI 401checked Oct. 4, 2026
Certified for: Lead, Nitrate
Brita Tahoe Pitcher with Elite Filter (OB60, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
- IAPMO listing:NSF/ANSI 53checked Oct. 13, 2026
Certified for: Lead
Brita Everyday Pitcher with Elite Filter (OB46, OB06)
Pitcher
- WQA listing:NSF/ANSI 42NSF/ANSI 53NSF/ANSI 401checked Oct. 13, 2026
Certified for: Lead
Violations since 2016
| Contaminant or rule | Type | Period | Measured | Status |
|---|---|---|---|---|
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | April 1, 2025 to June 30, 2025 | 11 MG/L | Resolved |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Jan. 1, 2025 to March 31, 2025 | 13 MG/L | Resolved |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Oct. 1, 2024 to Dec. 31, 2024 | 12 MG/L | Resolved |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Jan. 1, 2024 to March 31, 2024 | 12 MG/L | Resolved |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | April 1, 2023 to June 30, 2023 | 13 MG/L | Resolved |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Oct. 1, 2019 to Dec. 31, 2019 | 11.3 MG/L | Resolved |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Oct. 1, 2018 to Dec. 31, 2018 | 10.6 MG/L | Resolved |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | April 1, 2018 to June 30, 2018 | 12.6 MG/L | Resolved |
| Nitrate | A sample was above the legal limit, for a contaminant judged one sample at a time.EPA: Maximum Contaminant Level Violation, Single Sample | Oct. 1, 2017 to Dec. 31, 2017 | 11 MG/L | Resolved |
| Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 1 monitoring or reporting violation not shown. | ||||
What this report can’t tell you
Everything else. Nitrate, arsenic and total trihalomethanes (TTHM) results here are New Hampshire’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Chromium (total), fluoride and uranium come from EPA’s file alone, which ends in 2019. Northpointe Water’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for New Hampshire cover 2020 to 2023; EPA’s compliance samples are from Oct. 21, 2015 to Oct. 15, 2018.
Testing your own tap
The 3 labs New Hampshire certifies closest to the area Northpointe Water serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Laconia Water Works Laboratory
Lakeport, NH · about 27 miles
Certified for bacteria
Gorham Wastewater Treatment Facility Laboratory
Gorham, NH · about 34 miles
Certified for bacteria
Endyne Inc.
Lebanon, NH · about 37 miles
Certified for bacteria, nitrate
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- CDC Environmental Public Health Tracking Network, yearly averages New Hampshire supplied to CDC, 2020 to 2023, read Oct. 8, 2026. TapBuff’s comparisons with EPA’s limits are its own, not CDC’s or New Hampshire’s.
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: New Hampshire ELAP, drinking water labs, as listed in TNI LAMS, read Oct. 13, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID NH2342020. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Read up on the 2 results above a lineWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with Lead
- Get the utility’s own reportNorthpointe Water must send you a water quality report every year. It covers contaminants this page does not show, and has newer results than EPA’s national file for the ones here that come from it.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Compare certified filtersWhat the filters certified for these results cost over five years, cartridges included.Compare five-year costs