Skip to content
TapBuff

Lamington Hill

What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.

Serves
35 people
Connections
14
Water source
Groundwater
Based in
Stratham, NH
County
Rockingham
Owner
Private
The ZIP code it serves

03885

The short answer

2 results are above EPA’s legal limit, and 1 more is above the health goal. The worst: Lead, above the action level. 9 health-based violations since 2016.

What handles it

What was found

Lead and copper: EPA SDWIS monitoring periods ending 2023.

Arsenic, haloacetic acids (HAA5), nitrate and total trihalomethanes (TTHM): New Hampshire’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.

Uranium, chromium (total) and fluoride: EPA’s compliance monitoring file, samples taken from Oct. 6, 2016 to Dec. 9, 2019. Newer results are in the utility’s annual water quality report.

Above the legal limit2

Lead

Comes from pipes, often your own

Above the action level

18ppb

90th percentile, 2021 to 2023

In the latest period, 9 in 10 homes sampled were at or below 18 ppb, above EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027, and this result is at or above that. EPA’s health goal for lead is zero.

What handles it

Arsenic

Comes from the source

Above the legal limit

10.9ppb

Highest yearly average, 2020 to 2023

2023 average: 10.6 ppb

Averaged by year, the highest was 10.9 ppb, in 2022, above EPA’s legal limit of 10 ppb. In 2023, the latest year on file, it averaged 10.6 ppb, above the limit. EPA recorded violations for arsenic at this utility in 2022, 2023 and 2024. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 9.1 ppb, in 2016.

What handles it

  • NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
  • NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”

Above the health goal1

Uranium

Comes from the source

Above the health goal

1.0ppb

Highest yearly average, 2019

Averaged by year, the highest was 1.0 ppb, in 2019: below EPA’s legal limit of 30 ppb, but above its health goal of zero. That is the only year on file.

What handles it

5 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Chromium (total)
  • Fluoride
  • Haloacetic acids (HAA5)
  • Nitrate
  • Total trihalomethanes (TTHM)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

  • NSF/ANSI 53

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction

    For: Lead, Arsenic

    Other certifiers’ wording: Arsenic (III) (50 ppb influent level)

  • NSF/ANSI 58

    Claims: Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Uranium

    For: Lead, Arsenic, Uranium

    Other certifiers’ wording: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)

At the tap, or for the whole house?

Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for lead, ranked

The best reverse osmosis systems, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Lead and Copper RuleRequired information about lead was not given to customers.EPA: Public EducationFeb. 27, 2024—Resolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2024 to March 31, 20240.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2023 to Dec. 31, 20230.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2023 to Sept. 30, 20230.01 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2023 to June 30, 20230.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJan. 1, 2023 to March 31, 20230.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2022 to Dec. 31, 20220.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageJuly 1, 2022 to Sept. 30, 20220.011 MG/LResolved
ArsenicThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageApril 1, 2022 to June 30, 20220.01 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 9 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Arsenic, haloacetic acids (HAA5), nitrate and total trihalomethanes (TTHM) results here are New Hampshire’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Uranium, chromium (total) and fluoride come from EPA’s file alone, which ends in 2019. Lamington Hill’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for New Hampshire cover 2020 to 2023; EPA’s compliance samples are from Oct. 6, 2016 to Dec. 9, 2019.

Testing your own tap

Lamington Hill’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New Hampshire certifies.

The 3 labs New Hampshire certifies closest to the area Lamington Hill serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Eurofins Portsmouth

    Portsmouth, NH · about 6 miles

    Certified for bacteria

    (603) 436-2001

  • Seacoast Analytical Services LLC

    Lee, NH · about 7 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics

    (603) 868-1457

  • Eurofins Derry

    Derry, NH · about 21 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS

    (603) 432-3044

All 63 certified labs for New Hampshire

Sources

PWSID NH2232170. Rebuilt from EPA data on Oct. 18, 2026.