What EPA’s and CDC’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals, plus violations since 2016, with the certification that handles each result.

Serves
58 people
Connections
26
Water source
Groundwater
Based in
Tamworth, NH
County
Carroll
Owner
Private
The ZIP code it serves

03817

The short answer

1 result is above EPA’s legal limit, and 1 more is above the health goal. The worst: Fluoride, above the legal limit. 4 health-based violations since 2016.

What handles it

What was found

Uranium, arsenic, nitrate and total trihalomethanes (TTHM): New Hampshire’s yearly averages per water system, as CDC’s Environmental Public Health Tracking Network publishes them, 2020 to 2023, with EPA’s 2012 to 2019 file for earlier years.

Fluoride: EPA’s violation records from 2020 on, with EPA’s 2012 to 2019 file for earlier years.

Chromium (total): EPA’s compliance monitoring file, samples taken from Aug. 4, 2015 to Aug. 14, 2018. Newer results are in the utility’s annual water quality report.

Above the legal limit1

Fluoride

Forms or is added in treatment

Above the legal limit

4.9ppm

Limit violation, 2022

EPA recorded two violations of the legal limit for fluoride at this utility in 2020 and 2022. The highest measured level, for Oct. 1, 2022 to Sept. 30, 2023, was an average of 4.9 ppm, above EPA’s legal limit of 4.0 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.7 ppm, in 2019, and EPA recorded a violation in 2019.

What handles it

Above the health goal1

Uranium

Comes from the source

Above the health goal

1.1ppb

Highest yearly average, 2020 to 2023

2023: not found

Averaged by year, the highest was 1.1 ppb, in 2021: below EPA’s legal limit of 30 ppb, but above its health goal of zero. In 2023, the latest year on file, it wasn’t found. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 1.0 ppb, in 2016.

What handles it

Below EPA’s limits1

Chromium (total)

Comes from the source

Below EPA’s limits

2.0ppb

Highest yearly average, 2015 to 2018

Averaged by year, the highest was 2.0 ppb, in 2018, below EPA’s legal limit of 100 ppb. That was also the latest year on file.

What handles it

3 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Nitrate
  • Total trihalomethanes (TTHM)

What handles it

A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box. Wording varies a little: NSF writes “Lead Reduction,” WQA just “Lead.”

At the tap, or for the whole house?

These come with the water itself, so a whole-house system certified for the same claims treats every tap and shower. A filter at the tap treats drinking water for much less. How whole-house systems compare.

Filters with those claims on a certifier’s listing

Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money

Compare five-year costs

The best water filters for fluoride, ranked

Violations since 2016

Contaminant or ruleTypePeriodMeasuredStatus
Revised Total Coliform RuleColiform or E. coli results required a detailed review of the system, and it or its fixes were not done on time.EPA: Treatment Technique, Level 2 Assessment (RTCR)Feb. 12, 2024—Resolved
FluorideThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2022 to Sept. 30, 20234.9 MG/LResolved
FluorideThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2020 to Dec. 31, 20204.2 MG/LResolved
FluorideThe running average was above the legal limit.EPA: Maximum Contaminant Level Violation, AverageOct. 1, 2019 to Sept. 30, 202025 MG/LResolved
Health-based violations only. Resolved and archived mean the utility returned to compliance or the state closed the record. 3 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Uranium, arsenic, nitrate and total trihalomethanes (TTHM) results here are New Hampshire’s yearly averages as CDC publishes them, from 2020 on, with EPA’s national file for 2012 to 2019. Chromium (total) comes from EPA’s file alone, which ends in 2019. Chocorua Meadows’s own annual report, which it must send you every year, has newer results for those and the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; CDC’s yearly averages for New Hampshire cover 2020 to 2023; EPA’s compliance samples are from Aug. 4, 2015 to Aug. 14, 2018.

Testing your own tap

Chocorua Meadows’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab New Hampshire certifies.

The 3 labs New Hampshire certifies closest to the area Chocorua Meadows serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • Laconia Water Works Laboratory

    Lakeport, NH · about 25 miles

    Certified for bacteria

    (603) 524-1096

  • Gorham Wastewater Treatment Facility Laboratory

    Gorham, NH · about 28 miles

    Certified for bacteria

    (603) 466-3104

  • New Hampshire DHHS Public Health Laboratories

    Concord, NH · about 46 miles

    Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, radioactivity

    (603) 271-3445

All 63 certified labs for New Hampshire

Sources