Walker Switch Water Assn
EPA’s and Mississippi’s records have results for 33 contaminants in its water; 2 were found.
Serves 982 people · Groundwater bought from another system · Iuka, MS
- Serves
- 982 people
- Connections
- 372
- Water source
- Groundwater bought from another system
- Based in
- Iuka, MS
- County
- Tishomingo
- Owner
- Public and private
The ZIP code it serves
The short answer
None of the results here is above a limit in force today. That covers PFAS and lithium; nitrate, arsenic and other regulated chemicals; and lead and copper, not everything. No health-based violations on file since 2016.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from June 14 to Dec. 19, 2023.
Haloacetic acids (HAA5) and total trihalomethanes (TTHM): Mississippi’s own results, samples taken from Oct. 27, 2020 to Aug. 12, 2026.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Below EPA’s limits, 2 results
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 5.0 ppb
Highest yearly average, 2020 to 2026 · 2026: not found · Forms or is added in treatment
Averaged by year, the highest was 5.0 ppb, in 2020, below EPA’s legal limit of 60 ppb. In 2026, the latest year on file, it wasn’t found in its one sample.
What handles it
No certification claim covers this compound yet.
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 5.8 ppb
Highest yearly average, 2021 to 2026 · 2026, one sample: 4.6 ppb · Forms or is added in treatment
Averaged by year, the highest was 5.8 ppb, in 2023, below EPA’s legal limit of 80 ppb. In 2026, the latest year on file, its one sample was below the limit.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
31 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
From routine monitoring
- Lead
PFAS and lithium, from EPA’s UCMR 5 sampling
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
No health-based violations on file with EPA since 2016. There are 3 monitoring or reporting violations: a sample missed, late or not reported. EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Disinfectant
Walker Switch Water Assn reported adding no disinfectant at its one sampling point, in its 2023 sampling for EPA.
What that means
Most utilities add chlorine or chloramine, CDC says. This utility buys its water from another system, so what it reported may leave out treatment done before the water reaches it. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Haloacetic acids (HAA5) and total trihalomethanes (TTHM) results here are Mississippi’s own from 2020 on. Walker Switch Water Assn’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from June 14 to Dec. 19, 2023; Mississippi’s results run from Oct. 27, 2020 to Aug. 12, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Walker Switch Water Assn’s latest lead sampling in EPA’s records, 2021 to 2023, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
Labs Mississippi certifies, or a kit by mail
No lab Mississippi certifies is within 75 miles of the area Walker Switch Water Assn serves on the state’s list. Some take samples by mail; the state’s page lists them all.
All 5 certified labs for MississippiOr test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Mississippi certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Mississippi’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded
- Get the utility’s own reportWalker Switch Water Assn must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadIts latest lead sampling found none at the 90th percentile, but your own service line, solder and fixtures decide the lead at your faucet.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Mississippi State Department of Health, Bureau of Public Water Supply, results from Jan. 9, 2020 to Oct. 12, 2026, read Oct. 17, 2026
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID MS0710011. Rebuilt from EPA data on Oct. 25, 2026.