Broadmoor Utilities, Inc
EPA’s and Mississippi’s records have results for 39 contaminants in its water; 10 were found.
Serves 1,185 people · Groundwater · Natchez, MS
- Serves
- 1,185 people
- Connections
- 449
- Water source
- Groundwater
- Based in
- Natchez, MS
- County
- Adams
- Owner
- Public and private
The ZIP code it serves
The short answer
Copper is above the action level in the latest monitoring period, ending June 30, 2025. 1 health-based violation since 2016, with no fix on record in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from March 20, 2023 to Jan. 17, 2024.
Lead and copper: EPA SDWIS monitoring periods ending 2017 to 2025.
Fluoride, arsenic, uranium, nitrate, chromium (total), total trihalomethanes (TTHM) and haloacetic acids (HAA5): Mississippi’s own results, samples taken from March 2, 2020 to July 6, 2026.
What the lines mean
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. One other PFAS with no federal limit was found, the highest 6:2 FTS at 15.5 ppt: see it below.
Above the legal limit, 1 result
Copper
Comes from pipes, often your own
What it means for you. EPA’s concern is stomach and intestinal distress from short-term exposure, and liver or kidney damage over years. A filter certified for it, at the tap you drink from, reduces it.
1.9 ppm
90th percentile, 2025
In the latest period, 9 in 10 homes sampled were at or below 1.9 ppm, above EPA’s action level of 1.3 ppm.
What handles it
- NSF/ANSI 53 look for “Copper Reduction”
- NSF/ANSI 58 look for “Copper Reduction”
Below EPA’s limits, 8 results
Lead, arsenic and uranium have a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Legal limit (MCL):
- Enforceable. The most a utility may deliver.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Lead, Action level 15 ppb · health goal zero; 90th percentile 1.5 ppb
90th percentile, 2026 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 1.5 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.3 ppm
Highest yearly average, 2020 to 2026 · 2026, one sample: 0.3 ppm · Forms or is added in treatment
Averaged by year, the highest was 0.3 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. In 2026, the latest year on file, its one sample was below the limit.
What handles it
- NSF/ANSI 58 look for “Fluoride Reduction”
- NSF/ANSI 53 look for “Fluoride”
Arsenic, Legal limit 10 ppb · health goal zero; highest yearly average 0.72 ppb
Highest yearly average, 2020 to 2026 · 2026: not found · Comes from the source
Averaged by year, the highest was 0.72 ppb, in 2021, below EPA’s legal limit of 10 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 0.8 ppb. In 2026, the latest year on file, it wasn’t found in its one sample.
What handles it
- NSF/ANSI 58 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
- NSF/ANSI 53 look for “Arsenic (Pentavalent)<=50 ppb Reduction”
Uranium, Legal limit 30 ppb · health goal zero; highest yearly average 1.9 ppb
Highest yearly average, 2020 to 2021 · 2021 average: 1.6 ppb · Comes from the source
Averaged by year, the highest was 1.9 ppb, in 2020, below EPA’s legal limit of 30 ppb. Its health goal is zero, so any amount found is above it; the goal isn’t a limit. Its highest single sample was 2.0 ppb. In 2021, the latest year on file, its two samples averaged below the limit.
What handles it
- NSF/ANSI 58 look for “Uranium”
Nitrate, Legal limit 10 ppm; highest 0.54 ppm
Highest sample; found in 7 of 7 · 2026, one sample: 0.35 ppm · Comes from the source
The highest sample, in 2025, was 0.54 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
Chromium (total), Legal limit 100 ppb; highest yearly average 4.0 ppb
Highest yearly average, 2020 to 2026 · 2026, one sample: 3.4 ppb · Comes from the source
Averaged by year, the highest was 4.0 ppb, in 2024, below EPA’s legal limit of 100 ppb. Its highest single sample was 4.3 ppb. In 2026, the latest year on file, its one sample was below the limit.
What handles it
- NSF/ANSI 58 look for “Chromium (Hexavalent) Reduction”
- NSF/ANSI 53 look for “Chromium Reduction”
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 2.9 ppb
Highest yearly average, 2022 to 2025 · 2025, one sample: 1.8 ppb · Forms or is added in treatment
Averaged by year, the highest was 2.9 ppb, in 2023, below EPA’s legal limit of 80 ppb. Its highest single sample was 4.4 ppb. In 2025, the latest year on file, its one sample was below the limit.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 1.7 ppb
Highest yearly average, 2022 to 2024 · 2024 average: 0.37 ppb · Forms or is added in treatment
Averaged by year, the highest was 1.7 ppb, in 2022, below EPA’s legal limit of 60 ppb. Its highest single sample was 2.6 ppb. In 2024, the latest year on file, its seven samples averaged below the limit.
What handles it
No certification claim covers this compound yet.
Also found, with no federal limit
EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.
| Compound | Highest sample | Found in | Certification claim |
|---|---|---|---|
| 6:2 FTS | 15.5 ppt | 1 of 2 | None covers it |
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- Lithium
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
Violations since 2016
1 health-based violation since 2016 for the Groundwater Rule. It began June 15, 2020, and it has no fix on record in EPA’s file.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Groundwater Rule | A significant problem found in a state inspection was not fixed on time.EPA: Failure To Address Deficiency | June 15, 2020 | No fix on recordEPA: unaddressed |
Health-based violations only. 4 monitoring or reporting violations not shown.
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Copper Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction
For: Copper, Lead, Arsenic
Other claims that cover it: Arsenic (III) (50 ppb influent level)
- NSF/ANSI 58
Claims: Copper Reduction, Lead Reduction, Arsenic (Pentavalent)<=50 ppb Reduction, Uranium
For: Copper, Lead, Arsenic, Uranium
Other claims that cover it: Arsenic (Pentavalent)<=300 ppb Reduction; Arsenic (V) (300 ppb influent level)
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Copper; also lead and arsenic, found below their limits
Brita Tahoe Pitcher with Original Filter (OB60, OB03)
Pitcher
Five years: $1,124, household of 3, cartridges included
Certified for: Copper
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Copper; also lead and arsenic, found below their limits
2 more filters
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Copper; also lead and arsenic, found below their limits
LifeStraw Home 7-Cup Glass Water Filter Pitcher
Pitcher
Five years: $2,869, household of 3, cartridges included
Certified for: Copper; also lead, found below its limits
Every filter certified for it
Disinfectant
Broadmoor Utilities, Inc reported disinfecting with chlorine, not chloramine, at its one sampling point, in its 2023 to 2024 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
What this report can’t tell you
Everything else. Fluoride, arsenic, uranium, nitrate, chromium (total), total trihalomethanes (TTHM) and haloacetic acids (HAA5) results here are Mississippi’s own from 2020 on. Broadmoor Utilities, Inc’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 20, 2023 to Jan. 17, 2024; Mississippi’s results run from March 2, 2020 to July 6, 2026.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Broadmoor Utilities, Inc’s latest lead sampling in EPA’s records, 2026, had a 90th percentile of 1.5 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
Labs Mississippi certifies, or a kit by mail
No lab Mississippi certifies is within 75 miles of the area Broadmoor Utilities, Inc serves on the state’s list. Some take samples by mail; the state’s page lists them all.
All 5 certified labs for MississippiOr test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Mississippi certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Mississippi’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on copperWhat it does to health, where it comes from, and the certification claim that addresses it.About copper
- Get the utility’s own reportBroadmoor Utilities, Inc must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Mississippi State Department of Health, Bureau of Public Water Supply, results from Jan. 9, 2020 to Oct. 12, 2026, read Oct. 17, 2026
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID MS0010005. Rebuilt from EPA data on Oct. 25, 2026.