TapBuff
Menu

Rogerswater quality report, rewritten

Serves
14,430
Connections
3,500
Water source
Groundwater
Based in
Rogers, MN
County
Hennepin
Owner
Local government

ZIP codes served: 55374

PWSID MN12700472026 edition · EPA data

Read this first

  • Lithium was found in three of 6 samples, highest 20.4 ppb. Above EPA’s health reference level of 10 ppb, a screening level rather than an enforceable limit.

No health-based violations on file since 2016.

What was found

Highlighted: above the health goal. Circled: above the legal limit in at least one sample. Every scale puts the legal line at its middle.

Lithium

Comes from the source

20.4ppb

Highest of 6 samples; found in three

Above EPA’s health reference level of 10 ppb, a screening level rather than an enforceable limit.

What handles it

No certification claim covers this compound yet.

EPA UCMR 5, samples taken from April 9, 2025 to Nov. 20, 2025. Each blue tick is one sample where it was found.

Also found, with no federal limit

EPA measured these PFAS to learn how often they occur. None has a legal limit or a health goal yet.

CompoundHighest sampleFound inCertification claim
PFBA8.6 ppt2 of 6None covers it

Tested and not found

Below EPA’s minimum reporting level in every sample taken from April 9, 2025 to Nov. 20, 2025. Not found means not measured above that level, which is not the same as zero.

  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • Lead
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

Violations since 2016

No health-based violations on file with EPA since 2016.

What this report cannot tell you

  • Levels of everything else. Federal bulk data carries results for PFAS, lithium, lead and copper, and violations for the rest. Nitrate, arsenic, disinfection byproducts and other levels are in Rogers’s own annual report, which it must send you every year.
  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
  • Anything after the latest data. SDWIS data is from 2026 Q2; UCMR 5 samples are from April 9, 2025 to Nov. 20, 2025.