Michigan State University
EPA’s records have results for 32 contaminants in its water; 3 were found.
Serves 12,793 people · Groundwater · East Lansing, MI
- Serves
- 12,793 people
- Connections
- 300
- Water source
- Groundwater
- Based in
- East Lansing, MI
- County
- Ingham
- Owner
- Local government
The short answer
Copper is above the action level in the latest monitoring period, ending Dec. 31, 2023. Lithium is above EPA’s health benchmark. 1 health-based violation since 2016, resolved in EPA’s file.
This is what the records show, not medical advice. Worried about a health effect? Talk to a doctor or your local health department.
What was found
Where these results come from, and when
PFAS and lithium: EPA UCMR 5, samples taken from March 20 to Sept. 18, 2023.
Lead and copper: EPA SDWIS monitoring periods ending 2023.
What the lines mean
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
- Health goal (MCLG):
- Not enforceable. The level with no expected risk, with a margin of safety.
- Health reference level:
- A screening level from EPA’s work on whether to regulate a contaminant, where there is no legal limit or health goal; not enforceable.
PFAS: None of the six PFAS in EPA’s 2024 drinking water rule was found in this utility’s samples. None of the other 23 PFAS tested for was found either.
Above the legal limit, 1 result
Copper
Comes from pipes, often your own
What it means for you. EPA’s concern is stomach and intestinal distress from short-term exposure, and liver or kidney damage over years. A filter certified for it, at the tap you drink from, reduces it.
1.5 ppm
90th percentile, 2021 to 2023
In the latest period, 9 in 10 homes sampled were at or below 1.5 ppm, above EPA’s action level of 1.3 ppm.
What handles it
- NSF/ANSI 53 look for “Copper Reduction”
- NSF/ANSI 58 look for “Copper Reduction”
Above EPA’s health benchmark, 1 result
Lithium
Comes from the source
17 ppb
Highest sample, Sept. 11, 2023; found in 25 of 34
The highest sample was 17 ppb, above EPA’s health reference level of 10 ppb. That is a screening level, not an enforceable limit.
What handles it
No filter certification covers lithium yet, and EPA’s 2023 fact sheet says boiling doesn’t remove it. Because it was found, your utility has to report its lithium results in its annual water quality report, where newer ones will appear.
How to read your utility’s reportBelow EPA’s limits, 1 result
Lead has a health goal of zero: the level with no known or expected risk. Any amount found is above it, but the goal isn’t a limit.
- Action level:
- Triggers action. If more than 10% of homes sampled are above it, the utility must act.
- 90th percentile:
- How a lead or copper result is held against its action level: nine in ten of the homes sampled were at or below it.
Lead, Action level 15 ppb · health goal zero; 90th percentile 2.0 ppb
90th percentile, 2025 · Comes from pipes, often your own
In the latest period, 9 in 10 homes sampled were at or below 2.0 ppb, below EPA’s action level of 15 ppb. The action level drops to 10 ppb on Nov. 1, 2027. EPA’s health goal for lead is zero.
What handles it
- NSF/ANSI 53 look for “Lead Reduction”
- NSF/ANSI 58 look for “Lead Reduction”
29 compounds tested and not foundIncluding all six PFAS in EPA’s 2024 rule. Below the reporting level in every sample. Not found is not the same as zero.
- 11Cl-PF3OUdS
- 4:2 FTS
- 6:2 FTS
- 8:2 FTS
- 9Cl-PF3ONS
- ADONA
- HFPO-DA (GenX)
- NEtFOSAA
- NFDHA
- NMeFOSAA
- PFBA
- PFBS
- PFDA
- PFDoA
- PFEESA
- PFHpA
- PFHpS
- PFHxA
- PFHxS
- PFMBA
- PFMPA
- PFNA
- PFOA
- PFOS
- PFPeA
- PFPeS
- PFTA
- PFTrDA
- PFUnA
What handles it
A certification covers specific claims, not a whole standard. Look for these claims on the certifier’s listing, not the box.
- NSF/ANSI 53
Claims: Copper Reduction, Lead Reduction
For: Copper, Lead
- NSF/ANSI 58
Claims: Copper Reduction, Lead Reduction
For: Copper, Lead
At the tap, or for the whole house?
Lead and copper usually come from pipes and fixtures inside or near your home. A whole-house system sits where water enters, so it cannot catch what your own plumbing adds after it. For those, the filter that counts is the one at the tap. How whole-house systems compare.
Filters with those claims on a certifier’s listing
Disclosure: TapBuff earns a commission if you buy through some links on this page. It does not change which standard or filter we name. As an Amazon Associate, TapBuff earns from qualifying purchases. How TapBuff makes money
Under-sink reverse osmosis
Five years: $549, household of 3, cartridges included
WQA listing: NSF/ANSI 58, checked Oct. 9, 2026
Certified for: Copper; also lead, found below its limits
Brita Tahoe Pitcher with Original Filter (OB60, OB03)
Pitcher
Five years: $1,124, household of 3, cartridges included
Certified for: Copper
Countertop reverse osmosis
Five years: $1,344, household of 3, cartridges included
Certified for: Copper; also lead, found below its limits
2 more filters
Brondell Capella RC250 Reverse Osmosis System
Under-sink reverse osmosis
Five years: $1,950, household of 3, cartridges included
Certified for: Copper; also lead, found below its limits
LifeStraw Home 7-Cup Glass Water Filter Pitcher
Pitcher
Five years: $2,869, household of 3, cartridges included
Certified for: Copper; also lead, found below its limits
Disinfectant
Michigan State University reported chlorine, not chloramine, at 1 of its 17 sampling points, and no disinfectant at 16, in its 2023 sampling for EPA.
What that means
Chlorine leaves water that sits out for a few days, CDC says. A filter certified for it carries a chlorine claim under NSF/ANSI 42; a shower filter, a free chlorine claim under NSF/ANSI 177. This is what the utility reported for that sampling. Its annual water quality report says what it uses now.
Violations since 2016
1 health-based violation since 2016 for combined Radium (-226 and -228). It began July 1, 2025.
- Resolved:
- EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
- No fix on record:
- It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).
EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.
Got a notice about one? What it means and what to do| Contaminant or rule | What happened | Period, and what was measured | Status |
|---|---|---|---|
| Combined Radium (-226 and -228) | The running average was above the legal limit.EPA: Maximum Contaminant Level Violation, Average | July 1, 2025 to Sept. 30, 2025, 6.0 PCI/L | Resolved |
Health-based violations only. 3 monitoring or reporting violations not shown.
What this report can’t tell you
Newer results, and everything else. Michigan sent EPA no routine results for its 2012 to 2019 review, so this page has no routine nitrate, arsenic or disinfection byproduct results for Michigan State University. They are in its own annual report, which it must send you every year.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 samples are from March 20 to Sept. 18, 2023.
Testing your own tap
What to test for at your tap
- Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Michigan State University’s latest lead sampling in EPA’s records, 2025, had a 90th percentile of 2.0 ppb: 9 in 10 of the homes it sampled were at or below that. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
- What Michigan State University’s results flag: lithium. It is in the water the utility sends out, so a test of your tap mostly confirms it. Include it if you want a number for your own home.
The 3 labs Michigan certifies closest to the area Michigan State University serves, or a kit by mail
The 3 labs Michigan certifies closest to the area Michigan State University serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Merit Laboratories, Inc.
East Lansing, MI · about 5 miles
Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS
Metiri Group-Holt Formerly Fibertec
Holt, MI · about 9 miles
Certified for PFAS
EGLE Laboratory Services
Lansing, MI · about 12 miles
Certified for bacteria, nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts, PFAS, radioactivity
Or test by mail
Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Michigan certifies it for the test you want.
Tap Score
- Lead and Copper Water Test, with a pH test strip: $55
- Essential City Water Test, 25 metals, 4 minerals, nitrate, fluoride, hardness and pH: $189
Return shipping included.
Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Michigan’s list.
Prices from Tap Score’s own store on Oct. 22, 2026.
What to do now
- Read up on these 2 resultsWhat each one does to health, where it comes from, and the certification claim that addresses it.Start with copper
- Get the utility’s own reportMichigan State University must send you a water quality report every year. It has newer results than EPA’s national file, which ends in 2019.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Disinfectant: EPA UCMR 5 occurrence data, additional data elements, file of Oct. 15, 2026
- Certified labs: EGLE, State of Michigan certified drinking water laboratories, read Oct. 16, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID MI0004340. Rebuilt from EPA data on Oct. 25, 2026.