Hinsdale Water Dept
What EPA’s and Massachusetts’s records show in this utility’s water: nitrate, arsenic and other regulated chemicals; lead and copper; and violations since 2016, with the certification that handles each result.
- Serves
- 1,000 people
- Connections
- 424
- Water source
- Surface water
- Based in
- Hinsdale, MA
- County
- Berkshire
- Owner
- Local government
The ZIP code it serves
The short answer
Nothing in EPA’s and Massachusetts’s records for this utility is above a health goal. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. No health-based violations on file since 2016.
What was found
Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic, chromium (total) and fluoride: Massachusetts’s own results, samples taken from Feb. 18, 2020 to Aug. 20, 2026, with EPA’s 2012 to 2019 file for earlier years.
Below EPA’s limits3
Total trihalomethanes (TTHM)
Forms or is added in treatment
46.9ppb
Highest yearly average, 2020 to 2026
Averaged by year, the highest was 46.9 ppb, in 2026, below EPA’s legal limit of 80 ppb. Its highest single sample was 77.6 ppb. That was also the latest year on file. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 49.4 ppb, in 2019.
What handles it
- NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
- NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
Haloacetic acids (HAA5)
Forms or is added in treatment
29.8ppb
Highest yearly average, 2020 to 2026
2026 average: 29 ppb
Averaged by year, the highest was 29.8 ppb, in 2025, below EPA’s legal limit of 60 ppb. Its highest single sample was 50.2 ppb. In 2026, the latest year on file, its three samples averaged 29 ppb. Earlier, from 2012 to 2019, EPA’s file shows a highest yearly average of 40.1 ppb, in 2019.
What handles it
No certification claim covers this compound yet.
Nitrate
Comes from the source
0.27ppm
Highest sample; found in 6 of 7
2026, one sample: 0.079 ppm
The highest sample, in 2025, was 0.27 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was 0.079 ppm. Earlier, from 2012 to 2019, EPA’s file shows a highest sample of 0.12 ppm, in 2017.
What handles it
- NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
- NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
- Arsenic
- Chromium (total)
- Fluoride
- Lead
Violations since 2016
No health-based violations on file with EPA since 2016. There are 2 monitoring or reporting violations: a sample missed, late or not reported.
What this report can’t tell you
Everything else. Total trihalomethanes (TTHM), haloacetic acids (HAA5), nitrate, arsenic, chromium (total) and fluoride results here are Massachusetts’s own from 2020 on, with EPA’s national file for 2012 to 2019. Hinsdale Water Dept’s own annual report, which it must send you every year, has the contaminants this page does not show.
Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.
What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.
Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Massachusetts’s results run from Feb. 18, 2020 to Aug. 20, 2026.
Testing your own tap
The 3 labs Massachusetts certifies closest to the area Hinsdale Water Dept serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.
Microbac Laboratories Inc.
Lee, MA · about 12 miles
Certified for bacteria
Howard Laboratories LLC
South Deerfield, MA · about 23 miles
Certified for bacteria
Vallid Labs Inc.
Agawam, MA · about 34 miles
Certified for bacteria
Sources
- EPA UCMR 5 occurrence data, file of Oct. 15, 2026
- EPA SDWA bulk download (SDWIS federal data), 2026 Q3
- Massachusetts Department of Environmental Protection, Drinking Water Program, results from Jan. 2, 2020 to Oct. 5, 2026, read Oct. 8, 2026
- EPA Six-Year Review 4 compliance monitoring data, 2012 to 2019, file of Feb. 5, 2024
- Certified labs: MassDEP Online Searchable Laboratory Certification Listing, potable water, read Oct. 16, 2026; distances from the Census 2020 ZIP code tabulation area gazetteer
- Limits and goals: each contaminant’s page, with its EPA source.
- How this page is built: methodology.
PWSID MA1132000. Rebuilt from EPA data on Oct. 18, 2026.
What to do next
- Nothing here is above a health goalIn EPA’s and Massachusetts’s records for this utility. They don’t cover everything, which is why the next step matters.Every contaminant TapBuff tracks
- Get the utility’s own reportHinsdale Water Dept must send you a water quality report every year. It covers contaminants this page does not show.How to read it
- Test your own tap for leadYour service line, solder and fixtures decide the lead at your faucet, not the utility’s average.Lead in your water: what to do
- Decide if you want a filter at allA filter for taste or chlorine is a preference, not a need. The standards say what each kind can do.NSF/ANSI standards, decoded