Skip to content
TapBuff

Turkey Creek Water System

EPA’s and Louisiana’s records have results for 8 contaminants in its water; 4 were found.

Serves 3,429 people · Groundwater · Gilbert, LA

Serves
3,429 people
Connections
1,143
Water source
Groundwater
Based in
Gilbert, LA
County
Franklin Parish
Owner
Private
The 2 ZIP codes it serves

70585, 70586

The short answer

None of the results here is above a limit in force today. That covers nitrate, arsenic and other regulated chemicals, plus lead and copper, not everything. 15 health-based violations since 2016, 14 with no fix on record in EPA’s file.

The 15 violations⁠Got a notice? What it means⁠

What was found

Where these results come from, and when

Nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, arsenic, chromium (total) and uranium: Louisiana’s own results, samples taken from April 22, 2020 to Aug. 19, 2026, with EPA’s 2012 to 2019 file for earlier years.

What the lines mean
Legal limit (MCL):
Enforceable. The most a utility may deliver.
Health goal (MCLG):
Not enforceable. The level with no expected risk, with a margin of safety.

Below EPA’s limits, 4 results

Legal limit (MCL):
Enforceable. The most a utility may deliver.
Nitrate, Legal limit 10 ppm; highest 1.6 ppm

Highest sample; found in 9 of 9 · 2026, one sample: 1.0 ppm · Comes from the source

The highest sample, in 2024, was 1.6 ppm, below EPA’s legal limit of 10 ppm. In 2026, the latest year on file, its one sample was below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest sample of 2.3 ppm, in 2018.

What handles it

  • NSF/ANSI 58 look for “Nitrate/Nitrite Reduction”
  • NSF/ANSI 53 look for “Nitrate/Nitrite (30 ppm challenge)”
About nitrate
Total trihalomethanes (TTHM), Legal limit 80 ppb; highest yearly average 6.4 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 3.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 6.4 ppb, in 2020, below EPA’s legal limit of 80 ppb. Its highest single sample was 11.4 ppb. In 2026, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 5.1 ppb, in 2015.

What handles it

  • NSF/ANSI 53 look for “Trihalomethanes (TTHM) Reduction”
  • NSF/ANSI 58 look for “Trihalomethanes (TTHM) Reduction”
About total trihalomethanes (TTHM)
Haloacetic acids (HAA5), Legal limit 60 ppb; highest yearly average 3.4 ppb

Highest yearly average, 2020 to 2026 · 2026 average: 2.3 ppb · Forms or is added in treatment

Averaged by year, the highest was 3.4 ppb, in 2020, below EPA’s legal limit of 60 ppb. Its highest single sample was 6.2 ppb. In 2026, the latest year on file, its two samples averaged below the limit.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 4.2 ppb, in 2019.

What handles it

No certification claim covers this compound yet.

About haloacetic acids (HAA5)
Fluoride, Legal limit 4.0 ppm; highest yearly average 0.17 ppm

Highest yearly average, 2020 to 2024 · Forms or is added in treatment

Averaged by year, the highest was 0.17 ppm, in 2024, below EPA’s legal limit of 4.0 ppm. Its highest single sample was 0.2 ppm. That was also the latest year on file.

Earlier, 2012 to 2019

From 2012 to 2019, EPA’s file shows a highest yearly average of 0.29 ppm, in 2018.

What handles it

About fluoride
4 compounds tested and not foundBelow the reporting level in every sample. Not found is not the same as zero.
  • Arsenic
  • Chromium (total)
  • Lead
  • Uranium

Violations since 2016

15 health-based violations since 2016, all for the Groundwater Rule. The latest began Nov. 13, 2025, and 14 have no fix on record in EPA’s file.

Resolved:
EPA’s file records a resolving action. The utility came back into compliance, the rule no longer applied, or no further action was needed.
No fix on record:
It records none. EPA’s own word for these is archived, addressed or unaddressed, shown beside each (EPA’s definitions, updated Oct. 9, 2026).

EPA’s file runs to 2026 Q3, so a notice your utility sent since then may not be here yet.

Got a notice about one? What it means and what to do⁠
Health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencyNov. 13, 2025No fix on recordEPA: unaddressed
Nov. 13, 2025No fix on recordEPA: unaddressed
Sept. 20, 2023No fix on recordEPA: unaddressed
Sept. 20, 2023No fix on recordEPA: addressed
Sept. 20, 2023No fix on recordEPA: addressed
The other 10, back to 2019
Earlier health-based violations, newest first
Contaminant or ruleWhat happenedPeriod, and what was measuredStatus
Groundwater RuleA significant problem found in a state inspection was not fixed on time.EPA: Failure To Address DeficiencySept. 20, 2023No fix on recordEPA: unaddressed
Sept. 20, 2023No fix on recordEPA: addressed
Sept. 20, 2023No fix on recordEPA: unaddressed
Sept. 20, 2023No fix on recordEPA: addressed
Sept. 20, 2023No fix on recordEPA: unaddressed
Sept. 20, 2023No fix on recordEPA: unaddressed
Sept. 20, 2023No fix on recordEPA: addressed
Sept. 20, 2023No fix on recordEPA: unaddressed
July 1, 2022No fix on recordEPA: addressed
April 2, 2019Resolved

Health-based violations only. 4 monitoring or reporting violations not shown.

What this report can’t tell you

  • Everything else. Nitrate, total trihalomethanes (TTHM), haloacetic acids (HAA5), fluoride, arsenic, chromium (total) and uranium results here are Louisiana’s own from 2020 on, with EPA’s national file for 2012 to 2019. Turkey Creek Water System’s own annual report, which it must send you every year, has the contaminants this page does not show.

  • Your own plumbing. Lead results are the 90th percentile across homes the utility samples. Your home’s service line, solder and fixtures decide yours. A certified lab test is the only way to know.

  • What it means for your health. This page reports what the records show and EPA’s limits and goals; it is not medical advice. If you are worried about a health effect, talk to a doctor or your local health department.

  • Anything after the latest data. SDWIS data is from 2026 Q3; UCMR 5 didn’t sample this utility; Louisiana’s results run from April 22, 2020 to Aug. 19, 2026.

Testing your own tap

Turkey Creek Water System’s results are for the water it sends out. What your own service line, solder and fixtures add shows up only in a test of your tap, by a lab Louisiana certifies.

What to test for at your tap

  • Lead and copper. Both come mostly from a building’s own service line, solder and faucets, so a utility’s numbers can’t tell you yours. Turkey Creek Water System’s latest lead sampling in EPA’s records, 2023 to 2025, had a 90th percentile of 0 ppb across the homes it sampled. The action level is 15 ppb, dropping to 10 ppb in November 2027, and EPA’s health goal for lead is zero. About lead.
The 3 labs Louisiana certifies closest to the area Turkey Creek Water System serves, or a kit by mail

The 3 labs Louisiana certifies closest to the area Turkey Creek Water System serves, in a straight line. Call first: certification is test by test, and not every lab takes samples from homeowners.

  • LDH Rapides Regional Laboratory

    Alexandria, LA · about 34 miles

    Certified for bacteria

    (318) 487-5282

  • SGS North America, Inc. - Scott

    Scott, LA · about 41 miles

    Certified for nitrate, lead and copper, metals, minerals and other inorganics, organic chemicals, disinfection byproducts

  • Element Materials Technology Lafayette, LLC

    Lafayette, LA · about 50 miles

    Certified for lead and copper, metals

All 48 certified labs for Louisiana⁠

Or test by mail

Tap Score sells lab tests as kits you fill at your tap and mail back. The sample goes to Tap Score’s lab, not one near you, so check that Louisiana certifies it for the test you want.

  • Tap Score

    Return shipping included.

    Tap Score says each kit ships to “an accredited laboratory” but doesn’t name it, so TapBuff can’t check it against Louisiana’s list.

Prices from Tap Score’s own store on Oct. 22, 2026.

What to do now

Sources

PWSID LA1041012. Rebuilt from EPA data on Oct. 25, 2026.